Section V. Parameter Function Table
30
U0.13
Length value
1
Fb function group fixed length function Fb.05~Fb.07
U0.14
Load speed display
1
Motor actual running speed
U0.15
PID set point
1
PID percentage of reference value for running adjustment.
U0.16
PID feedback
1
PID percentage of feedback value for running adjustment.
U0.17
PLC stage
1
PLC program running stage-display
U0.18
PULSE pulse input frequency(kHz)
0.01kHz
Display PULSE pulse input frequency
,
unit 0.01Khz
U0.19
Speed feedback(Unit 0.1Hz)
0.1Hz
synchronous speed
,
accurate to 0.1hz
U0.20
Surplus running time
0.1Min
Display surplus running time, used for regular operation control.
U0.21
AI1 voltage before correction
0.001V
AI1 voltage before correction ,used for AC function group parameter AC.00~AC.03 to correct AI1 voltage
U0.22
AI2 voltage before correction
0.001V
AI2 voltage before correction ,used for AC function group parameter AC.04~AC.07 to correct AI2 voltage
U0.23
AI3 voltage before correction
0.001V
AI3 voltage before correction ,used for AC function group parameter AC.08~AC.11 to correct AI3 voltage
U0.24
Linear velocity
1m/Min
Linear velocity is calculated according to angular velocity and diameter, used for constant tension control
and constant linear velocity control.
U0.25
Current power on time
1Min
The cumulative power on time of the inverter.
U0.26
Current running time
0.1Min
The cumulative running time of the inverter.
U0.27
PULSE pulse input frequency
1Hz
Display PULSE pulse input frequency
,
unit 1Hz.
U0.28
Communication set value
0.01%
Communication set value
U0.29
Encoder feedback speed
0.01Hz
PG feedback speed, accurate to 0.1hz