Scheduled Turbine Maintenance
Inspection and Maintenance — GEK 107048
STM-3
5. Note loose or vibrating piping conduit, or other fittings, and schedule repairs if necessary.
6. Check faces of clutch for cleanliness or possible damage. Clean or schedule maintenance as appro-
priate.
7. Inspect for evidence of overheating of accessory components (such as paint discoloration), and
schedule maintenance inspection or test of suspect components.
Off-Base Systems
1. Note loose or vibrating piping, conduit, or fittings. Schedule maintenance action if required.
2. Clean the floors of dirt, water, fuel, or lubricating oil spills. Dispose of rags and other debris.
General
1. Check door seals for deterioration. Schedule replacement as required.
2. Observe shutdown oil levels for the turbine, atomizing air compressor, atomizing air booster com-
pressor and turning gear. Note discrepancies, investigate cause, and refill all components to proper
oil levels as required.
Data Recording
Operating data should be recorded to permit an evaluation of equipment performance and maintenance
requirements. Typical data includes load, exhaust temperature, vibration, fuel flow and pressure, exhaust
temperature control and variation, and startup time.
The vibration level of the unit should be observed and recorded. Minor changes in vibration level will
occur with changes in operating conditions. However, major changes in the vibration level or a continu-
ously increasing trend to increase warrants corrective action.
The fuel system should be observed for general fuel flow versus load relationship. Fuel pressures through
the system should be observed. Changes in fuel pressure may indicate that fuel nozzle passages are
plugged (dirty) or that fuel metering elements are damaged or out of calibration.
The variation in turbine exhaust temperature should be measured. An increase in temperature spread indi-
cates combustion system deterioration or fuel distribution problems. If this is not corrected, reduced life
of downstream parts can be expected.
One of the most important control functions to be observed is the exhaust temperature control system, and
its backup overtemperature trip circuitry. Routine verification of the operation and calibration of these
systems will minimize wear on the hot gas path parts.
Startup time (when the gas turbine is new) is an excellent reference to which subsequent operating parame-
ters can be compared and evaluated. A curve of starting parameters of speed, fuel VCE signal, exhaust
temperature, and critical sequence benchmarks versus time from the initial start signal provide a good in-
dication of the accuracy of the control system, fuel system, fuel nozzles, ignition, and combustion system.
Deviations from normal conditions help pinpoint impending trouble, changes in calibration, or damaged
components.
Содержание MS6001B
Страница 2: ...Gas Turbine Inspection and Maintenance GEK 107048 I 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 4: ...Inspection and Maintenance Note THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 12: ...Inspection and Maintenance Notes Cautions and Warnings viii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 13: ...INSERT TAB INTRODUCTION ...
Страница 14: ......
Страница 25: ...INSERT TAB STANDARD PRACTICES ...
Страница 26: ......
Страница 57: ...Standard Practices Inspection and Maintenance GEK 107048 SP 31 Figure 2 26 Rail Fabrication Hoist ...
Страница 58: ...Inspection and Maintenance GEK 107048 Standard Practices SP 32 Figure 2 27 Pulley Nozzle Segments ...
Страница 59: ...Standard Practices Inspection and Maintenance GEK 107048 SP 33 Figure 2 28 Typical Borescope Kit ...
Страница 60: ...Inspection and Maintenance GEK 107048 Standard Practices SP 34 Figure 2 29 Rail Channel Trolley ...
Страница 61: ...Standard Practices Inspection and Maintenance GEK 107048 SP 35 Figure 2 30 Lifting Beam Inlet Silencer ...
Страница 62: ...Inspection and Maintenance GEK 107048 Standard Practices SP 36 Figure 2 31 Lifting Beam Inlet Transition ...
Страница 63: ...Standard Practices Inspection and Maintenance GEK 107048 SP 37 Figure 2 32 Lifting Beam Inlet Elbow ...
Страница 66: ...Inspection and Maintenance GEK 107048 Standard Practices SP 40 Figure 2 38 Tubing Insert and Male Connector ...
Страница 86: ...Inspection and Maintenance GEK 107048 Standard Practices SP 60 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 87: ...INSERT TAB AUXILIARY CONTROLS SYSTEMS MAINTENANCE ...
Страница 88: ......
Страница 90: ...Auxiliary and Controls Systems Maintenance Inspection and Maintenance THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 104: ...Auxiliary and Controls Systems Maintenance Inspection and Maintenance ACSM 14 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 106: ...Inspection and Maintenance Procedures Inspection and Maintenance I 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 132: ...Inspection and Maintenance Procedures Inspection and Maintenance IMP 26 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 133: ...INSERT TAB SCHEDULED TURBINE MAINTENACE ...
Страница 134: ......
Страница 153: ...Scheduled Turbine Maintenance Inspection and Maintenance GEK 107048 STM 19 Figure 4 2 Borescope Light Supply ...
Страница 156: ...Inspection and Maintenance GEK 107048 Scheduled Turbine Maintenance STM 22 Figure 4 5 TV Monitor Presentation ...
Страница 157: ...INSERT TAB COMBUSTION INSPECTION ...
Страница 158: ......
Страница 160: ...Inspection and Maintenance GEK 107048 Combustion Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 239: ...INSERT TAB HOT GAS PATH INSPECTION ...
Страница 240: ......
Страница 242: ...Inspection and Maintenance GEK 107048 Hot Gas Path Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 313: ...INSERT TAB MAJOR INSPECTION ...
Страница 314: ......
Страница 316: ...Inspection and Maintenance GEK 107048 Major Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 350: ...Inspection and Maintenance GEK 107048 Major Inspection Inspection Procedures MI I 8 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 363: ...INSERT TAB MAINTENANCE FORMS ...
Страница 364: ......
Страница 370: ...Inspection and Maintenance GEK 107048 Maintenance Forms MF 6 THIS PAGE INTENTIONALLY LEFT BLANK ...