Inspection and Maintenance Procedures
Inspection and Maintenance
IMP–16
CAUTION
Any physical damage to fire detectors such as but not lim-
ited to distortion, dents, twisting will cause the fire detec-
tors to loose their calibration and serviceability. If any
physical damage is found on the fire detectors they should
be replaced.
Open flames such as propane or acetylene torches are not
to be used under any circumstances to check the operation
of detectors. The use of propane or acetylene torches
causes severe drifting or destruction of the detectors
internals.
If the fire detectors are functioning properly, they will pickup relay 45FTX to trip the turbine. The fire
alarm bell in the accessory compartment should ring and the fire flag on the annunciator should drop.
High Pressure System Tests
Two separate tests are necessary to ensure that the high pressure system is ready for operation. These
tests are: (1) Solenoid Pilot Valve test and (2) “Puff” test. Description of the test procedure can be found
under the Fire Protection tab of the Service Manual.
Low-Pressure CO
2
System Electric Release and “Puff” Tests
This system consists of a single pressure vessel, refrigeration system, gauges, alarm system and safety
vent assembly, all enclosed within a steel housing on a single, all-welded base. The refrigeration system
automatically maintains the CO
2
in the pressure vessel at approximately 0
°
F (–17.7
°
C) and a vapor pres-
sure of 300 psi (20.6 bars).
Operation of the low-pressure CO
2
system is fully automatic. Once installation is complete, the system
requires only periodic inspection and maintenance (except when fire protection service, or system mal-
function necessitates major servicing and checkout).
**WARNING**
Carbon dioxide, in a concentration sufficient to extin-
guish fire, creates an atmosphere that will not support
life. It is extremely hazardous to enter the compart-
ments after the CO
2
system has been discharged. Any-
one rendered unconscious by carbon dioxide should be
rescued as quickly as possible and revived immediate-
ly with artificial respiration or by mouth- to-mouth re-
suscitation. The extent and type of safeguards and per-
sonnel warnings that may be necessary must be de-
signed to meet the particular requirements of each sit-
uation. It is recommended that personnel be adequate-
ly trained to cope with such an emergency.
Содержание MS6001B
Страница 2: ...Gas Turbine Inspection and Maintenance GEK 107048 I 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 4: ...Inspection and Maintenance Note THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 12: ...Inspection and Maintenance Notes Cautions and Warnings viii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 13: ...INSERT TAB INTRODUCTION ...
Страница 14: ......
Страница 25: ...INSERT TAB STANDARD PRACTICES ...
Страница 26: ......
Страница 57: ...Standard Practices Inspection and Maintenance GEK 107048 SP 31 Figure 2 26 Rail Fabrication Hoist ...
Страница 58: ...Inspection and Maintenance GEK 107048 Standard Practices SP 32 Figure 2 27 Pulley Nozzle Segments ...
Страница 59: ...Standard Practices Inspection and Maintenance GEK 107048 SP 33 Figure 2 28 Typical Borescope Kit ...
Страница 60: ...Inspection and Maintenance GEK 107048 Standard Practices SP 34 Figure 2 29 Rail Channel Trolley ...
Страница 61: ...Standard Practices Inspection and Maintenance GEK 107048 SP 35 Figure 2 30 Lifting Beam Inlet Silencer ...
Страница 62: ...Inspection and Maintenance GEK 107048 Standard Practices SP 36 Figure 2 31 Lifting Beam Inlet Transition ...
Страница 63: ...Standard Practices Inspection and Maintenance GEK 107048 SP 37 Figure 2 32 Lifting Beam Inlet Elbow ...
Страница 66: ...Inspection and Maintenance GEK 107048 Standard Practices SP 40 Figure 2 38 Tubing Insert and Male Connector ...
Страница 86: ...Inspection and Maintenance GEK 107048 Standard Practices SP 60 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 87: ...INSERT TAB AUXILIARY CONTROLS SYSTEMS MAINTENANCE ...
Страница 88: ......
Страница 90: ...Auxiliary and Controls Systems Maintenance Inspection and Maintenance THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 104: ...Auxiliary and Controls Systems Maintenance Inspection and Maintenance ACSM 14 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 106: ...Inspection and Maintenance Procedures Inspection and Maintenance I 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 132: ...Inspection and Maintenance Procedures Inspection and Maintenance IMP 26 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 133: ...INSERT TAB SCHEDULED TURBINE MAINTENACE ...
Страница 134: ......
Страница 153: ...Scheduled Turbine Maintenance Inspection and Maintenance GEK 107048 STM 19 Figure 4 2 Borescope Light Supply ...
Страница 156: ...Inspection and Maintenance GEK 107048 Scheduled Turbine Maintenance STM 22 Figure 4 5 TV Monitor Presentation ...
Страница 157: ...INSERT TAB COMBUSTION INSPECTION ...
Страница 158: ......
Страница 160: ...Inspection and Maintenance GEK 107048 Combustion Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 239: ...INSERT TAB HOT GAS PATH INSPECTION ...
Страница 240: ......
Страница 242: ...Inspection and Maintenance GEK 107048 Hot Gas Path Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 313: ...INSERT TAB MAJOR INSPECTION ...
Страница 314: ......
Страница 316: ...Inspection and Maintenance GEK 107048 Major Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 350: ...Inspection and Maintenance GEK 107048 Major Inspection Inspection Procedures MI I 8 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 363: ...INSERT TAB MAINTENANCE FORMS ...
Страница 364: ......
Страница 370: ...Inspection and Maintenance GEK 107048 Maintenance Forms MF 6 THIS PAGE INTENTIONALLY LEFT BLANK ...