Inspection and Maintenance Procedures
Inspection and Maintenance
IMP–8
cific conditions. A light sludge, or scale coating, on either side of the tube greatly reduces its effective-
ness. A marked increase in pressure drop and/or reduction in performance usually indicates cleaning is
necessary. Since the difficulty of cleaning increases rapidly as the scale thickens or deposits increase,
the intervals between cleanings should not be excessive.
To clean or inspect the inside of the tubes, remove only the necessary tube side channel covers or bonnets,
depending on the type of exchanger construction.
To clean or inspect the outside of the tubes, it may be necessary to remove the tube bundle. (Fixed tube
sheet exchanger bundles are non-removable.)
If an exchanger tube should develop a leak, it may be possible to plug the tube in the heat exchanger and
continue using the bundle. Consult GE for information concerning how many tubes may be plugged in
a given heat exchanger and still have the heat exchanger perform satisfactorily in gas turbine service.
The tapered plug material which is selected should be compatible with the heat exchanger bundle materi-
al. Stainless steel plugs are compatible with stainless steel heat exchanger tubes. Brass plugs are recom-
mended for 90-10 copper-nickel tubes or for brass tubes or for admirality metal tubes. These plugs are
installed in the leaking tube at the tube sheet using a nylon or rawhide hammer to prevent inadvertent
damage.
Radiator and Header Assemblies
For maximum effectiveness of the overall cooling system, the fins of the fin-tube radiator assemblies
must be kept free of bugs, lint, oil film, and other debris. The fins should be cleaned in the direction oppo-
site to normal flow. Washing with water, or a commercially available radiator fin cleanser will be ade-
quate. Refer to the paragraphs on Cooling Water System maintenance for information relative to fouling
of the inside of the radiator tubes. Check the radiator also for leakage, corrosion, erosion, or damage to
the fins or tubes. Refer to the Cooling Water System tab in this Service Manual for cleaning the radiators.
Lube Oil Immersion Heaters
These steel sheath heaters are designed for non-circulating oil application. The heaters have to be fully
immersed in a liquid while energized.
Mist Eliminator
The pressure drop across the unit should be checked at startup and periodically during operation. Refer
to the lube oil system schematic piping diagram in the Reference Drawing section of this Service Manu-
al. A high pressure drop could indicate, (1) the mist eliminator elements are plugging with solids, or (2)
the oil vapor flow rate is too high. A low pressure drop could indicate bypassing of some sort, particularly
if smoke is visible.
Mist Eliminator Fan
Periodically check the fan wheel and housing for cleanliness. If there is excessive vibration, or high bear-
ing temperature, it may indicate motor bearing wear, blade wear, or a build up of dirt. Also check the
tightness of the mounting bolts and set screws. (See Standard Maintenance Items in this section for motor
inspection.)
Содержание MS6001B
Страница 2: ...Gas Turbine Inspection and Maintenance GEK 107048 I 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 4: ...Inspection and Maintenance Note THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 12: ...Inspection and Maintenance Notes Cautions and Warnings viii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 13: ...INSERT TAB INTRODUCTION ...
Страница 14: ......
Страница 25: ...INSERT TAB STANDARD PRACTICES ...
Страница 26: ......
Страница 57: ...Standard Practices Inspection and Maintenance GEK 107048 SP 31 Figure 2 26 Rail Fabrication Hoist ...
Страница 58: ...Inspection and Maintenance GEK 107048 Standard Practices SP 32 Figure 2 27 Pulley Nozzle Segments ...
Страница 59: ...Standard Practices Inspection and Maintenance GEK 107048 SP 33 Figure 2 28 Typical Borescope Kit ...
Страница 60: ...Inspection and Maintenance GEK 107048 Standard Practices SP 34 Figure 2 29 Rail Channel Trolley ...
Страница 61: ...Standard Practices Inspection and Maintenance GEK 107048 SP 35 Figure 2 30 Lifting Beam Inlet Silencer ...
Страница 62: ...Inspection and Maintenance GEK 107048 Standard Practices SP 36 Figure 2 31 Lifting Beam Inlet Transition ...
Страница 63: ...Standard Practices Inspection and Maintenance GEK 107048 SP 37 Figure 2 32 Lifting Beam Inlet Elbow ...
Страница 66: ...Inspection and Maintenance GEK 107048 Standard Practices SP 40 Figure 2 38 Tubing Insert and Male Connector ...
Страница 86: ...Inspection and Maintenance GEK 107048 Standard Practices SP 60 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 87: ...INSERT TAB AUXILIARY CONTROLS SYSTEMS MAINTENANCE ...
Страница 88: ......
Страница 90: ...Auxiliary and Controls Systems Maintenance Inspection and Maintenance THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 104: ...Auxiliary and Controls Systems Maintenance Inspection and Maintenance ACSM 14 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 106: ...Inspection and Maintenance Procedures Inspection and Maintenance I 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 132: ...Inspection and Maintenance Procedures Inspection and Maintenance IMP 26 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 133: ...INSERT TAB SCHEDULED TURBINE MAINTENACE ...
Страница 134: ......
Страница 153: ...Scheduled Turbine Maintenance Inspection and Maintenance GEK 107048 STM 19 Figure 4 2 Borescope Light Supply ...
Страница 156: ...Inspection and Maintenance GEK 107048 Scheduled Turbine Maintenance STM 22 Figure 4 5 TV Monitor Presentation ...
Страница 157: ...INSERT TAB COMBUSTION INSPECTION ...
Страница 158: ......
Страница 160: ...Inspection and Maintenance GEK 107048 Combustion Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 239: ...INSERT TAB HOT GAS PATH INSPECTION ...
Страница 240: ......
Страница 242: ...Inspection and Maintenance GEK 107048 Hot Gas Path Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 313: ...INSERT TAB MAJOR INSPECTION ...
Страница 314: ......
Страница 316: ...Inspection and Maintenance GEK 107048 Major Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 350: ...Inspection and Maintenance GEK 107048 Major Inspection Inspection Procedures MI I 8 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 363: ...INSERT TAB MAINTENANCE FORMS ...
Страница 364: ......
Страница 370: ...Inspection and Maintenance GEK 107048 Maintenance Forms MF 6 THIS PAGE INTENTIONALLY LEFT BLANK ...