Inspection and Maintenance
Inspection and Maintenance Procedures
IMP–7
AC Motors
Examine the collector rings, brushes, brush holders and studs for cleanliness and wear. Collector rings
should maintain their polished surface. Brushes should move freely within their holders, but set firmly
in contact with the collector rings. Be sure the pigtail conductors are securely fastened to the brush hold-
ers. Check the insulation for cleanliness and wear.
Check the vibration of the motor while it is coupled to the pump. The vibration should not exceed 3 mils
(0.08 m). Check the cooling passages and louvers of the motor to make sure they are clean, undamaged
and unobstructed. Check rpm of motor with mechanical or Reed type tack and compare to nameplate.
COUPLINGS
Inspect couplings between motors and/or between motors and pumps for deterioration, missing or loose
hardware and cleanliness. Refer to the Service Manual under systems noted for further information.
UNIT PIPING SYSTEMS
Oil, Water and Air
A walk around visual inspection should be made to check piping systems for leaks, loose hardware, loose
hangers, leaky gaskets, valve packing leaks, vibration of piping, vents are functioning and a general
check for security of the systems. Corrective action should be taken to correct any abnormalities found.
LUBE SYSTEMS MAINTENANCE
Lube System Oil Pumps
Check the lube oil pumps for excessive vibration. Check the thrust bearings and bearing seal for wear.
Check the clearance of the wear ring. If wear has increased this clearance to 0.016 in. (0.041 cm), the
wear ring should be replaced.
Lube Oil Tank
Check the internal tubing and piping of the lube oil tank for peeling of paint and loose fittings. Check
the pipe hangers for loose or missing hardware. Carefully inspect each pump intake screen (especially
on the main pump) for foreign material and loose hardware. Check the sludge removed from the bottom
of the tank for the presence of unusual material. Make sure the inside of the tank is thoroughly clean
before refilling.
Lube Oil Properties
For instructions on determining lube oil physical properties and periodic sampling and testing, refer to
the Fluid Specifications Tab in Volume II of the Service Manual.
Heat Exchangers
Check the heat exchanger for leakage, efficient operation and foreign matter contamination. Exchangers
are subject to fouling (scale, sludge deposits, etc.) and should be cleaned periodically, depending on spe-
Содержание MS6001B
Страница 2: ...Gas Turbine Inspection and Maintenance GEK 107048 I 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 4: ...Inspection and Maintenance Note THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 12: ...Inspection and Maintenance Notes Cautions and Warnings viii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 13: ...INSERT TAB INTRODUCTION ...
Страница 14: ......
Страница 25: ...INSERT TAB STANDARD PRACTICES ...
Страница 26: ......
Страница 57: ...Standard Practices Inspection and Maintenance GEK 107048 SP 31 Figure 2 26 Rail Fabrication Hoist ...
Страница 58: ...Inspection and Maintenance GEK 107048 Standard Practices SP 32 Figure 2 27 Pulley Nozzle Segments ...
Страница 59: ...Standard Practices Inspection and Maintenance GEK 107048 SP 33 Figure 2 28 Typical Borescope Kit ...
Страница 60: ...Inspection and Maintenance GEK 107048 Standard Practices SP 34 Figure 2 29 Rail Channel Trolley ...
Страница 61: ...Standard Practices Inspection and Maintenance GEK 107048 SP 35 Figure 2 30 Lifting Beam Inlet Silencer ...
Страница 62: ...Inspection and Maintenance GEK 107048 Standard Practices SP 36 Figure 2 31 Lifting Beam Inlet Transition ...
Страница 63: ...Standard Practices Inspection and Maintenance GEK 107048 SP 37 Figure 2 32 Lifting Beam Inlet Elbow ...
Страница 66: ...Inspection and Maintenance GEK 107048 Standard Practices SP 40 Figure 2 38 Tubing Insert and Male Connector ...
Страница 86: ...Inspection and Maintenance GEK 107048 Standard Practices SP 60 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 87: ...INSERT TAB AUXILIARY CONTROLS SYSTEMS MAINTENANCE ...
Страница 88: ......
Страница 90: ...Auxiliary and Controls Systems Maintenance Inspection and Maintenance THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 104: ...Auxiliary and Controls Systems Maintenance Inspection and Maintenance ACSM 14 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 106: ...Inspection and Maintenance Procedures Inspection and Maintenance I 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 132: ...Inspection and Maintenance Procedures Inspection and Maintenance IMP 26 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 133: ...INSERT TAB SCHEDULED TURBINE MAINTENACE ...
Страница 134: ......
Страница 153: ...Scheduled Turbine Maintenance Inspection and Maintenance GEK 107048 STM 19 Figure 4 2 Borescope Light Supply ...
Страница 156: ...Inspection and Maintenance GEK 107048 Scheduled Turbine Maintenance STM 22 Figure 4 5 TV Monitor Presentation ...
Страница 157: ...INSERT TAB COMBUSTION INSPECTION ...
Страница 158: ......
Страница 160: ...Inspection and Maintenance GEK 107048 Combustion Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 239: ...INSERT TAB HOT GAS PATH INSPECTION ...
Страница 240: ......
Страница 242: ...Inspection and Maintenance GEK 107048 Hot Gas Path Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 313: ...INSERT TAB MAJOR INSPECTION ...
Страница 314: ......
Страница 316: ...Inspection and Maintenance GEK 107048 Major Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 350: ...Inspection and Maintenance GEK 107048 Major Inspection Inspection Procedures MI I 8 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 363: ...INSERT TAB MAINTENANCE FORMS ...
Страница 364: ......
Страница 370: ...Inspection and Maintenance GEK 107048 Maintenance Forms MF 6 THIS PAGE INTENTIONALLY LEFT BLANK ...