Inspection and Maintenance
Inspection and Maintenance Procedures
IMP–15
System Package Lagging
The joints in the lagging panels, roof, doors, and base should be inspected for tightness. If the joints are
not tight, the loss of medium will be too great to be replenished. The concentration will not buildup inside
the compartments to the required value. The easiest way to make the inspection is to stand inside each
compartment on a bright, sunny day with the lights off. No light should be visible through the joints.
Particular attention should be paid to all doors. The joint between the generator compartment and the
back side of the exhaust plenum, plus the joint between the generator and the turbine base should be
checked in particular. In general, joints which are not tight should be fitted with new gaskets. Doors can
be tightened by adjusting the striker plates.
High Pressure System
The fire protection system should be visually inspected to see that it is in proper working order. The pres-
sure gauges on the pilot-operated cylinders should be checked to be sure the cylinders are at the proper
pressure. The pressure is dependent on the cylinder temperature. For carbon dioxide, at 50
°
F (10
°
C) the
pressure should be about 650 psig (44.8 bars); at 70
°
F (21
°
C) about 840 psig (57.9 bars); at 105
°
F (41
°
C)
about 1250 psig (86.2 bars ). For Halon 1301, at 50
°
F (10
°
C) the pressure should be about 530 psig (36.5
bars); at 70
°
F (21
°
C) about 600 psig (41.4 bars); at 105
°
F (41
°
C) about 750 psig (51.7 bars). Check the
dampers to ensure they are unobstructed and properly latched.
High Pressure Storage Cylinders
Disconnect the discharge heads from all cylinders and the solenoid pilot valve assemblies from the pilot
cylinder. Weigh each cylinder. If a cylinder shows more than 10 percent loss in net weight, it should be
refilled, or replaced.
The empty and full weights of all cylinders are permanently stamped on the cylinder valve bodies. Each
time the cylinders are weighed, the date and net weight should be recorded on the attached tag.
Fire Detectors
CAUTION
If the fire detectors are checked in place, without removal
from the system, the discharge heads must be removed
from the medium cylinders to disarm the high pressure
system. The isolation valve must be closed in the low pres-
sure control cabinet to disable the low pressure system.
The temperature setting of the detector is stamped on its identification plate. It is not possible to accurate-
ly check the calibration of the detector. If it is suspected that a detector is out of calibration, it should
be replaced.
Содержание MS6001B
Страница 2: ...Gas Turbine Inspection and Maintenance GEK 107048 I 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 4: ...Inspection and Maintenance Note THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 12: ...Inspection and Maintenance Notes Cautions and Warnings viii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 13: ...INSERT TAB INTRODUCTION ...
Страница 14: ......
Страница 25: ...INSERT TAB STANDARD PRACTICES ...
Страница 26: ......
Страница 57: ...Standard Practices Inspection and Maintenance GEK 107048 SP 31 Figure 2 26 Rail Fabrication Hoist ...
Страница 58: ...Inspection and Maintenance GEK 107048 Standard Practices SP 32 Figure 2 27 Pulley Nozzle Segments ...
Страница 59: ...Standard Practices Inspection and Maintenance GEK 107048 SP 33 Figure 2 28 Typical Borescope Kit ...
Страница 60: ...Inspection and Maintenance GEK 107048 Standard Practices SP 34 Figure 2 29 Rail Channel Trolley ...
Страница 61: ...Standard Practices Inspection and Maintenance GEK 107048 SP 35 Figure 2 30 Lifting Beam Inlet Silencer ...
Страница 62: ...Inspection and Maintenance GEK 107048 Standard Practices SP 36 Figure 2 31 Lifting Beam Inlet Transition ...
Страница 63: ...Standard Practices Inspection and Maintenance GEK 107048 SP 37 Figure 2 32 Lifting Beam Inlet Elbow ...
Страница 66: ...Inspection and Maintenance GEK 107048 Standard Practices SP 40 Figure 2 38 Tubing Insert and Male Connector ...
Страница 86: ...Inspection and Maintenance GEK 107048 Standard Practices SP 60 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 87: ...INSERT TAB AUXILIARY CONTROLS SYSTEMS MAINTENANCE ...
Страница 88: ......
Страница 90: ...Auxiliary and Controls Systems Maintenance Inspection and Maintenance THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 104: ...Auxiliary and Controls Systems Maintenance Inspection and Maintenance ACSM 14 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 106: ...Inspection and Maintenance Procedures Inspection and Maintenance I 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 132: ...Inspection and Maintenance Procedures Inspection and Maintenance IMP 26 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 133: ...INSERT TAB SCHEDULED TURBINE MAINTENACE ...
Страница 134: ......
Страница 153: ...Scheduled Turbine Maintenance Inspection and Maintenance GEK 107048 STM 19 Figure 4 2 Borescope Light Supply ...
Страница 156: ...Inspection and Maintenance GEK 107048 Scheduled Turbine Maintenance STM 22 Figure 4 5 TV Monitor Presentation ...
Страница 157: ...INSERT TAB COMBUSTION INSPECTION ...
Страница 158: ......
Страница 160: ...Inspection and Maintenance GEK 107048 Combustion Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 239: ...INSERT TAB HOT GAS PATH INSPECTION ...
Страница 240: ......
Страница 242: ...Inspection and Maintenance GEK 107048 Hot Gas Path Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 313: ...INSERT TAB MAJOR INSPECTION ...
Страница 314: ......
Страница 316: ...Inspection and Maintenance GEK 107048 Major Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 350: ...Inspection and Maintenance GEK 107048 Major Inspection Inspection Procedures MI I 8 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 363: ...INSERT TAB MAINTENANCE FORMS ...
Страница 364: ......
Страница 370: ...Inspection and Maintenance GEK 107048 Maintenance Forms MF 6 THIS PAGE INTENTIONALLY LEFT BLANK ...