Inspection and Maintenance
Inspection and Maintenance Procedures
IMP–5
With lock washers installed, verify that the servovalve mounting screws are long enough to provide 1
to 1.5 times the screw diameter of thread engagement.
If longer servovalve mounting screws are required to meet minimum thread engagement, verify that the
replacement screw does not bottom in the threaded hole. Rework the screw if required.
Torque all servovalve mounting screws to 17–19 inch pounds.
Check Valves, Orifices and Orifice Check Valves
During a shutdown period, the system has to be drained and the valves and orifices have to be removed
to check for evidence of erosion, corrosion, or component deterioration. Check the orifices for plugging,
size and sharpness of the hole. Check the valve seat for leakage. Check the condition of the seals, “O”
rings, or gaskets, and replace them if there is any indication of wear.
Lube Oil Filters
The lube oil system filters should be changed once a year, regardless of the pressure drop. The pressure
drops must be checked under turbine operating conditions, with the lubricant at normal operating tem-
perature, and at rated flow through the filter. In most gas turbine lube systems, the main lube filter, which
filters the lubricant to the main bearing header, can be checked for clogging by the pressure drop indica-
tion. Here, the pressure downstream from the filter is maintained by a pressure regulating valve, and the
difference in the pressures shown on the gauges before and after the filter will provide a reliable indica-
tion of the filter condition. The condition of other filters in the lube system, such as the control fluid filter
or hydraulic control pump filter, cannot be determined as reliably by the pressure drop indication since
the flow through these filters may be very low under steady-state conditions. It is unlikely, however, that
these low-flow filters will foul before the recommended annual changeout of the filter element.
On gas turbines that are expected to run continuously over long periods of time, dual filter arrangements,
with a transfer valve, are usually incorporated into the lube system to facilitate the servicing of the filters
without turbine shutdown. Systems with single filter arrangements require that the turbine be shut down
to service the filters.
Hydraulic Supply Filters
The hydraulic supply system filter should be changed when the pressure drop across the filter is 60 psig
(4.14 bars), or once a year, regardless of the pressure drop.
The pressure drop must be checked under turbine operating conditions, with the hydraulic fluid at oper-
ating temperature and at rated flow through the filter. The rated flow can be assumed to be realized during
maximum transient conditions, such as at the instant of hydraulic tripout of the gas turbine. Under
steady-state conditions, there will be only a small flow through the filter and any differential pressure
indicated on the system gauge will probably be small and not a true indication of the condition of the
filter. It is unlikely, however that these low-flow filters will foul before the recommended annual change-
out of the filter cartridge.
On gas turbines that are expected to run continuously over long periods of time, dual-filter arrange-
ments, with a transfer valve, are usually incorporated into the hydraulic supply system to facilitate serv-
icing of the filters without turbine shutdown. Systems with single-filter arrangements require that the
turbine be shut down to service the filters.
Содержание MS6001B
Страница 2: ...Gas Turbine Inspection and Maintenance GEK 107048 I 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 4: ...Inspection and Maintenance Note THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 12: ...Inspection and Maintenance Notes Cautions and Warnings viii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 13: ...INSERT TAB INTRODUCTION ...
Страница 14: ......
Страница 25: ...INSERT TAB STANDARD PRACTICES ...
Страница 26: ......
Страница 57: ...Standard Practices Inspection and Maintenance GEK 107048 SP 31 Figure 2 26 Rail Fabrication Hoist ...
Страница 58: ...Inspection and Maintenance GEK 107048 Standard Practices SP 32 Figure 2 27 Pulley Nozzle Segments ...
Страница 59: ...Standard Practices Inspection and Maintenance GEK 107048 SP 33 Figure 2 28 Typical Borescope Kit ...
Страница 60: ...Inspection and Maintenance GEK 107048 Standard Practices SP 34 Figure 2 29 Rail Channel Trolley ...
Страница 61: ...Standard Practices Inspection and Maintenance GEK 107048 SP 35 Figure 2 30 Lifting Beam Inlet Silencer ...
Страница 62: ...Inspection and Maintenance GEK 107048 Standard Practices SP 36 Figure 2 31 Lifting Beam Inlet Transition ...
Страница 63: ...Standard Practices Inspection and Maintenance GEK 107048 SP 37 Figure 2 32 Lifting Beam Inlet Elbow ...
Страница 66: ...Inspection and Maintenance GEK 107048 Standard Practices SP 40 Figure 2 38 Tubing Insert and Male Connector ...
Страница 86: ...Inspection and Maintenance GEK 107048 Standard Practices SP 60 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 87: ...INSERT TAB AUXILIARY CONTROLS SYSTEMS MAINTENANCE ...
Страница 88: ......
Страница 90: ...Auxiliary and Controls Systems Maintenance Inspection and Maintenance THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 104: ...Auxiliary and Controls Systems Maintenance Inspection and Maintenance ACSM 14 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 106: ...Inspection and Maintenance Procedures Inspection and Maintenance I 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 132: ...Inspection and Maintenance Procedures Inspection and Maintenance IMP 26 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 133: ...INSERT TAB SCHEDULED TURBINE MAINTENACE ...
Страница 134: ......
Страница 153: ...Scheduled Turbine Maintenance Inspection and Maintenance GEK 107048 STM 19 Figure 4 2 Borescope Light Supply ...
Страница 156: ...Inspection and Maintenance GEK 107048 Scheduled Turbine Maintenance STM 22 Figure 4 5 TV Monitor Presentation ...
Страница 157: ...INSERT TAB COMBUSTION INSPECTION ...
Страница 158: ......
Страница 160: ...Inspection and Maintenance GEK 107048 Combustion Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 239: ...INSERT TAB HOT GAS PATH INSPECTION ...
Страница 240: ......
Страница 242: ...Inspection and Maintenance GEK 107048 Hot Gas Path Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 313: ...INSERT TAB MAJOR INSPECTION ...
Страница 314: ......
Страница 316: ...Inspection and Maintenance GEK 107048 Major Inspection 2 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 350: ...Inspection and Maintenance GEK 107048 Major Inspection Inspection Procedures MI I 8 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 363: ...INSERT TAB MAINTENANCE FORMS ...
Страница 364: ......
Страница 370: ...Inspection and Maintenance GEK 107048 Maintenance Forms MF 6 THIS PAGE INTENTIONALLY LEFT BLANK ...