Event Types for Alarms
EPICenter Reference Guide
534
Configuring SNMP Trap Events
There are a number of SNMP events that require configuration on the switch before they can be used in
EPICenter alarm definitions. If the configuration is not done on the switch, no trap events are
generated, and no EPICenter alarms for those events can occur. The Ping and OSPF traps fall into this
category.
To configure the switch to send one of these traps, you must use a tool that allows you to set the value
of the appropriate SNMP variable. Tools such as SNMPc can be used to perform this function. The
following information assumes that you have a thorough understanding of SNMP and an appropriate
SNMP utility.
Refer to the appropriate MIBs for details of the variable settings:
●
Ping MIB: pingmib.mib (RFC 2925)
●
OSPF v2 MIB: RFC 1850 or RFC 1850t
Wireless Port Boot
Failed
Extreme Networks proprietary trap. Sent by the platform if a
wireless port fails to boot too many times.
ExtremeWare 7.3
Not supported in
ExtremeXOS
Wireless Port State
Changed
Extreme Networks proprietary trap. Generated when a wireless
port moves into enabled, disabled, or online state.
ExtremeWare 7.3
Not supported in
ExtremeXOS
Wireless Probe Info
Added
Extreme Networks proprietary trap. Generated when a new
station is added to the probe info table. Generated only if the
value of extremeWirelessProbeInfoSendAddedTrap is true.
ExtremeWare 7.3
Not supported in
ExtremeXOS
Wireless Probe Info
Removed
Extreme Networks proprietary trap. Generated when a station is
removed from the probe info table. Generated only if the value
of extremeWirelessProbeInfoSendRemovedTrap is true.
ExtremeWare 7.3
Not supported in
ExtremeXOS
lldp Remote Table
Changed
A lldpRemTablesChange notification is sent when the value of
lldpStatsRemTableLastChangeTime changes. It can be utilized
by an NMS to trigger LLDP remote systems table maintenance
polls.
Note that transmission of lldpRemTablesChange notifications
are throttled by the agent, as specified by the
'lldpNotificationInterval' object.
ExtremeXOS 11.4/
Supported by Avaya
devices
Table 59: Trap Variable Configuration
Trap
Variables
Ping Probe Failed
set pingCtlTrapGeneration bit 0 ON to enable trap.
set pingCtlTrapProbeFailureFilter to specify the number of
successive probe failures that must occur to generate a Probe
Failed trap.
Ping Test Failed
set pingCtlTrapGeneration bit 1 ON to enable trap.
set pingCtlTrapTestFailureFilter to specify the number of
successive test failures that must occur to generate a Test Failed
trap.
Ping Test Completed
set pingCtlTrapGeneration bit 2 ON to enable the trap.
Table 58: SNMP Trap Events (continued)
Event
Definition
ExtremeWare/
ExtremeXOS
Version
Содержание EPICenter 6.0
Страница 14: ...EPICenter Reference Guide 14 ...
Страница 18: ...Preface EPICenter Reference Guide 18 ...
Страница 19: ...1 EPICenter Basic Features ...
Страница 20: ......
Страница 24: ...EPICenter Overview EPICenter Reference Guide 24 ...
Страница 44: ...Getting Started with EPICenter EPICenter Reference Guide 44 ...
Страница 100: ...The Inventory Manager EPICenter Reference Guide 100 ...
Страница 140: ...The EPICenter Alarm System EPICenter Reference Guide 140 ...
Страница 172: ...Configuration Manager EPICenter Reference Guide 172 ...
Страница 196: ...The Firmware Manager EPICenter Reference Guide 196 ...
Страница 220: ...The Interactive Telnet Feature EPICenter Reference Guide 220 ...
Страница 250: ...The Grouping Manager EPICenter Reference Guide 250 ...
Страница 276: ...Real Time Statistics EPICenter Reference Guide 276 ...
Страница 295: ...The New Menu EPICenter Reference Guide 295 Figure 137 Example of a default layout for a 500 node map ...
Страница 342: ...Using the VLAN Manager EPICenter Reference Guide 342 ...
Страница 348: ...The ESRP Monitor EPICenter Reference Guide 348 ...
Страница 446: ...EPICenter Reports EPICenter Reference Guide 446 ...
Страница 447: ...2 Advanced Upgrade Features ...
Страница 448: ......
Страница 480: ...EAPS Protocol Monitoring and Verification EPICenter Reference Guide 480 ...
Страница 508: ...Using the Policy Manager EPICenter Reference Guide 508 ...
Страница 525: ...3 Appendices ...
Страница 526: ......
Страница 542: ...EPICenter Backup EPICenter Reference Guide 542 ...
Страница 564: ...Voice over IP Manager EPICenter Reference Guide 564 ...
Страница 580: ...EPICenter Reference Guide 580 ...