The EPICenter Alarm System
EPICenter Reference Guide
134
It is important to understand that, except for the initial occurrence of the alarm, an RMON alarm event
is generated only the when the sample value of the variable crosses one of the thresholds for the first
time after having crossed the other threshold.
NOTE
To configure an alarm using an RMON threshold event, select RMON Rising or RMON Falling as the Event Type.
Configuring CPU Utilization Rules
NOTE
CPU Utilization is only supported on switches running ExtremeWare 6.2 or later.
If you select
CPU Utilization
as the Configuration Type, only the Rising Threshold field allows input, as
shown in
Figure 59
. The other fields and buttons in this window are predefined.
Sample Interval
(seconds)
The interval, in seconds, over which the data is sampled and compared to the rising and falling
thresholds.
Startup Alarm
The condition that should be met to cause the initial occurrence of this event. Select from the
following:
• Rising: An event is generated the first time the sample value becomes greater than or equal
to the Rising Threshold value. No events are generated related to the Falling threshold until
after this has occurred.
• Falling: An event is generated the first time the sample value becomes less than or equal to
the Falling Threshold value. No events are generated related to the Rising threshold until
after this has occurred.
• RisingOrFalling: An event is generated the first time the sample value becomes either greater
than or equal to the Rising Threshold value, or less than or equal to the Falling Threshold
value.
Содержание EPICenter 6.0
Страница 14: ...EPICenter Reference Guide 14 ...
Страница 18: ...Preface EPICenter Reference Guide 18 ...
Страница 19: ...1 EPICenter Basic Features ...
Страница 20: ......
Страница 24: ...EPICenter Overview EPICenter Reference Guide 24 ...
Страница 44: ...Getting Started with EPICenter EPICenter Reference Guide 44 ...
Страница 100: ...The Inventory Manager EPICenter Reference Guide 100 ...
Страница 140: ...The EPICenter Alarm System EPICenter Reference Guide 140 ...
Страница 172: ...Configuration Manager EPICenter Reference Guide 172 ...
Страница 196: ...The Firmware Manager EPICenter Reference Guide 196 ...
Страница 220: ...The Interactive Telnet Feature EPICenter Reference Guide 220 ...
Страница 250: ...The Grouping Manager EPICenter Reference Guide 250 ...
Страница 276: ...Real Time Statistics EPICenter Reference Guide 276 ...
Страница 295: ...The New Menu EPICenter Reference Guide 295 Figure 137 Example of a default layout for a 500 node map ...
Страница 342: ...Using the VLAN Manager EPICenter Reference Guide 342 ...
Страница 348: ...The ESRP Monitor EPICenter Reference Guide 348 ...
Страница 446: ...EPICenter Reports EPICenter Reference Guide 446 ...
Страница 447: ...2 Advanced Upgrade Features ...
Страница 448: ......
Страница 480: ...EAPS Protocol Monitoring and Verification EPICenter Reference Guide 480 ...
Страница 508: ...Using the Policy Manager EPICenter Reference Guide 508 ...
Страница 525: ...3 Appendices ...
Страница 526: ......
Страница 542: ...EPICenter Backup EPICenter Reference Guide 542 ...
Страница 564: ...Voice over IP Manager EPICenter Reference Guide 564 ...
Страница 580: ...EPICenter Reference Guide 580 ...