Configuring a New Rule or Modifying a Rule
EPICenter Reference Guide
135
Figure 59: New Configuration window for a CPU Utilization Rule
The fields displayed are defined as follows:
For a CPU Utilization event, the other parameters, such as the MIB variable, threshold, etc., are
predefined by the Extreme switch agent to be the following:
NOTE
To define an alarm for a CPU Utilization threshold event, select SNMP Trap as the Event Type, then select CPU
Utilization Rising Threshold or CPU Utilization Falling Threshold as the Event Name.
If you define an alarm for a CPU Utilization Rising Threshold event, an alarm is generated each time
the sample value meets the following conditions:
●
The sample value becomes greater than or equal to the Rising Threshold for the first time (including
the initial sample) after the alarm is enabled. (This is the startup condition.)
Rule Name
For CPU Utilization, the name is predefined because there can only be one rule of this type
on a device.
Rising Threshold
A threshold value, in percent, that triggers an event when the CPU utilization rises past this
value. This value is also used to compute a falling threshold, which is defined as 80% of
the rising threshold.
Description
The description of the
extremeCpuUtilRisingThreshold
MIB variable.
MIB Variable
The MIB variable is predefined to be
extremeCpuUtilRisingThreshold.0
.
Falling Threshold
This is predefined as 80% of the rising threshold.
Sample Interval
The sample interval for a CPU Utilization alarm is also predefined, and is set to 3 seconds.
Sample Type
The sample value (a percentage) is always an absolute value.
Startup Alarm
The Startup condition is predefined to be Rising.
Содержание EPICenter 6.0
Страница 14: ...EPICenter Reference Guide 14 ...
Страница 18: ...Preface EPICenter Reference Guide 18 ...
Страница 19: ...1 EPICenter Basic Features ...
Страница 20: ......
Страница 24: ...EPICenter Overview EPICenter Reference Guide 24 ...
Страница 44: ...Getting Started with EPICenter EPICenter Reference Guide 44 ...
Страница 100: ...The Inventory Manager EPICenter Reference Guide 100 ...
Страница 140: ...The EPICenter Alarm System EPICenter Reference Guide 140 ...
Страница 172: ...Configuration Manager EPICenter Reference Guide 172 ...
Страница 196: ...The Firmware Manager EPICenter Reference Guide 196 ...
Страница 220: ...The Interactive Telnet Feature EPICenter Reference Guide 220 ...
Страница 250: ...The Grouping Manager EPICenter Reference Guide 250 ...
Страница 276: ...Real Time Statistics EPICenter Reference Guide 276 ...
Страница 295: ...The New Menu EPICenter Reference Guide 295 Figure 137 Example of a default layout for a 500 node map ...
Страница 342: ...Using the VLAN Manager EPICenter Reference Guide 342 ...
Страница 348: ...The ESRP Monitor EPICenter Reference Guide 348 ...
Страница 446: ...EPICenter Reports EPICenter Reference Guide 446 ...
Страница 447: ...2 Advanced Upgrade Features ...
Страница 448: ......
Страница 480: ...EAPS Protocol Monitoring and Verification EPICenter Reference Guide 480 ...
Страница 508: ...Using the Policy Manager EPICenter Reference Guide 508 ...
Страница 525: ...3 Appendices ...
Страница 526: ......
Страница 542: ...EPICenter Backup EPICenter Reference Guide 542 ...
Страница 564: ...Voice over IP Manager EPICenter Reference Guide 564 ...
Страница 580: ...EPICenter Reference Guide 580 ...