Test Setup - Test Configurator, Timer, and System
286
88000 Series
Services - Profile
CBS
check box when selected (default) sets the maximum committed
burst size to which services’ frames will be sent and be CIR-compliant
(default is
12144
bytes). The CBS minimum and maximum values are
affected by the
CIR
,
Burst Max Rate
, and
Frame Size
values. CBS is
only available when CIR check box is selected.
EBS
check box when selected (cleared by default) sets the maximum
excess burst size to which services’ frames will be sent and be
CIR+EIR compliant (default is
12144
bytes). The EBS minimum and
maximum values are affected by the
CIR+EIR
,
Burst Max Rate
, and
Frame Size values
. EBS is only available when
CIR+EIR
check box is
selected.
Performance Criteria
Max Jitter (ms)
allows setting the maximum jitter value in
millisecond, allowed for the service:
0.015
to
8000 ms
(default is
2 ms
).
Max Round-Trip Latency (ms)
allows setting the maximum round-trip
latency value in millisecond allowed for the service:
0.015
to
8000 ms
(default is
15 ms
). For
Dual Test Set
, only available with
Round-Trip
Latency Measurement Mode
(see
available in
Dual Port
topology.
Max Latency
, available for
Dual Test Set
with
One-Way Latency
Measurement Mode
(see
on page 168) and Dual Port
topology, allows setting the maximum one-way latency allowed for the
service:
0.015
to
500 ms
(default is
15 ms
).
Frame Loss Rate
allows setting the maximum rate of Frame Loss
allowed for the service:
0.0E00
to
5.0E-02
, default is
1.0E-03
.
Note:
For Dual Test Set, the Frame Loss Rate is changed to percentage when the
remote module does not support exponential notation. In this case a Frame
Loss Rate Threshold lower than 1.0E-06 (0.0001 %) is considered as 0 %; the
configurable range is
0
to
5
%.
Содержание Power Blazer 88000 Series
Страница 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Страница 12: ......
Страница 16: ......
Страница 22: ......
Страница 28: ......
Страница 38: ......
Страница 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Страница 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Страница 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Страница 550: ......
Страница 670: ......
Страница 674: ......
Страница 686: ......
Страница 707: ...Glossary Power Blazer 695 10G Ethernet Client The following figure presents a typical network application ...
Страница 721: ...Glossary Power Blazer 709 Ethernet Cables Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s ...
Страница 765: ...Glossary Power Blazer 753 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values ...