Test Setup - Test Configurator, Timer, and System
238
88000 Series
ODU Channels - Global
Bit Error
Pass/Fail Verdict
allows enabling bit-error-rate pass/fail verdict by
selecting either
Bit Error Count
or
Bit Error Rate
. The default value is
Disabled
.
BER Threshold
allows entering the threshold
Count
or
Rate
value that
will be used to declare the pass/fail verdict.
For
Count
, enter the maximum bit error count allowed before
declaring a fail verdict:
0
(default) to
999999
.
For
Rate
, enter the maximum bit error rate allowed before declaring a
fail verdict:
1.0E-14
to
1.9E-01
. The default value is
1.0E-12
.
Service Disruption
The Service Disruption Time (SDT) corresponds to the duration associated
to a defect that occurred in the network. For example a disruption that
occurs during a network switching from the active channels to the backup
channels or vice versa.
Disruption Monitoring
check box when selected (disabled by
default) enables the disruption time measurements. However, the
measurement will only start if the test is already started, or when the
test is started.
Note:
Clearing the
Disruption Monitoring
check box will stop the measurement
without clearing the results. The disruption monitoring is automatically
stopped without clearing results when the test is stopped. However, starting
the test again while the
Disruption Monitoring
check box is selected will
reset the results before restarting.
Note:
The service disruption measurements are cleared when changing the
criteria.
Содержание Power Blazer 88000 Series
Страница 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Страница 12: ......
Страница 16: ......
Страница 22: ......
Страница 28: ......
Страница 38: ......
Страница 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Страница 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Страница 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Страница 550: ......
Страница 670: ......
Страница 674: ......
Страница 686: ......
Страница 707: ...Glossary Power Blazer 695 10G Ethernet Client The following figure presents a typical network application ...
Страница 721: ...Glossary Power Blazer 709 Ethernet Cables Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s ...
Страница 765: ...Glossary Power Blazer 753 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values ...