Test Results
446
88000 Series
PTP Stats
PTP Stats
From the
Test
menu, tap
Results
, and the
PTP Stats
tab.
TX/RX PTP Message Count/Rate
Gives the transmitted/received count and average rate for each PTP
message, and the total count for all messages.
Note:
In the case where messages are lost while the Receipt Timeout is set to a
large value (slow communication), the last valid recorded rate value will
be preceded with
<
to indicate that the reception rate is not stable. This
applies to
Delay Resp
,
Announce
,
Sync
, and
Follow UP
.
Note:
When the rate is above 150 messages/s,
> 150
is displayed.
TX
RX
Signaling Announce Req
a
Signaling Sync Req
Signaling Delay Resp Req
Delay Req
a.
The rate value corresponds to an average rate because these messages are only
transmitted/received when negotiating or renewing the lease with the Grand Master
clock. If the connection with the Grand Master Clock was already established when the
test is started, the
0
value is displayed. However, the value becomes available with the
next lease renewal which happens every 150 seconds. Only available with G.8265.1
profile.
Signaling Announce Grant
Signaling Sync Grant
Signaling Delay Resp Grant
Delay Resp
Sync
Follow Up
Announce
Содержание Power Blazer 88000 Series
Страница 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Страница 12: ......
Страница 16: ......
Страница 22: ......
Страница 28: ......
Страница 38: ......
Страница 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Страница 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Страница 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Страница 550: ......
Страница 670: ......
Страница 674: ......
Страница 686: ......
Страница 707: ...Glossary Power Blazer 695 10G Ethernet Client The following figure presents a typical network application ...
Страница 721: ...Glossary Power Blazer 709 Ethernet Cables Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s ...
Страница 765: ...Glossary Power Blazer 753 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values ...