Test Results
Power Blazer
373
Alarms/Errors Overview
GMP and ODTU4.1 - GMP (Generic Mapping
Procedure)
Note:
GMP is only available with EoOTN client (ODU0 with PT21). GMP is
displayed under ODUx alarms/errors group.
GMP
is labelled as
ODTU4.1 - GMP
with Multi-Channel OTN.
Alarms
OOS
(Generic Mapping Procedure - Out Of Synchronization).
RX
: Indicates that the GMP RX cannot synchronize with the GMP TX.
Errors
Cm-CRC-8
RX
: There is a Cm-CRC-8 mismatch between the received value and
the locally computed value.
CnD-CRC-5
RX
: There is a CnD-CRC-5 mismatch between the received value and
the locally computed value.