Test Setup - Test Configurator, Timer, and System
Power Blazer
259
RFC 2544 - Subtests
Frame Loss Configuration
The objective of this test is to find the percentage of frames that are lost
due to lack of resources. Starting at the specified maximum rate (
Max.
Rate
), the test is performed for a specific frame size and for the specified
duration
(Trial Duration)
. The test is repeated by decreasing the rate by
the specified granularity (
Granularity
), then the test is repeated again until
there are two successive trials in which no frames are lost. The test is
performed for the defined number of trials (
Trials
). The test is performed
for each defined frame size.
Max. Rate
is the maximum rate the test should begin with, in terms of
a percentage of the line rate (
%
),
Mbit/s
, or
Gbit/s
. The accepted
values are as shown in the Max. Rate table on page 256. For
Dual Test
Set
,
Max. Rate
is configurable for both local to remote (
L->R
) and
remote to local (
R->L
) directions. For
Dual Port
topology, Max. Rate is
configurable for both P1 to P2 (
P1->P2
) and P2 to P1 (
P2->P1
)
directions.
Trial Duration
represents the time value for each trial in
minutes:seconds:
1
second to
30
minutes (default is
00:01
).
Trials
represents the number of times the test will be generated:
1
(default) to
50
trials.
Granularity
corresponds to the percentage interval between each
throughput value used for the test: 1 % to 10 % (RFC) - (default). For
example, 10 % granularity means that the test will be performed for
100 %, 90 %, 80 %... of the rate value.
Содержание Power Blazer 88000 Series
Страница 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Страница 12: ......
Страница 16: ......
Страница 22: ......
Страница 28: ......
Страница 38: ......
Страница 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Страница 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Страница 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Страница 550: ......
Страница 670: ......
Страница 674: ......
Страница 686: ......
Страница 707: ...Glossary Power Blazer 695 10G Ethernet Client The following figure presents a typical network application ...
Страница 721: ...Glossary Power Blazer 709 Ethernet Cables Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s ...
Страница 765: ...Glossary Power Blazer 753 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values ...