Test Results
366
88000 Series
Alarms/Errors Overview
Fibre Channel
Alarms
Link Down
RX
: The Fibre Channel connection is down meaning that there is a
local or a remote fault condition.
Local Fault Detected
(FC 10X)
RX
: Indicates that at least one of the following events is detected:
LOS
,
Loss of bit synchronization
,
Loss of Block synchronization
,
Link
down
, or
High BER
(High BER is true when the bit error ratio > 10
-4
on
a fixed 125
μ
s time period).
Local Fault Received
(FC 10X)
RX
: Indicates that the received data path contains the Local Fault
signal.
Remote Fault
(FC 10X)
RX
: Indicates that a Remote Fault event is detected.