background image

 

SUNLOVER HEATING 

WARRANTY – SL6 ELITE 

 
This product is covered by a limited 2 year warranty against component failure or faulty 
workmanship from the date of installation.  
Temperature sensors are covered by a limited 12 month warranty. 
 
A faulty unit should be returned in the first instance to the dealer from which the unit was 
purchased. 
 
Damage  to  the  unit  due  to  misuse,  power  surges,  lightning  strikes  or  installation  that  is 
not in accordance with the manufacturer’s instruction may void the warranty.  
 
If the power cord is damaged, do not use the controller; return the unit to the 
supplier for repair 
 
Warranty does not cover travel or freight / postage costs to or from installation site. 
 
Return to supplier for repair 
 

Customer Record

. (To be retained by the customer) 

 
 
Dealer/Installer Name……………………………………………… 
 
Model Number……………………… 
 
Serial Number………………………. 
 
Date Installed……………………….. 
 
………………………………………………………………………… 
 
For service assistance phone SUNLOVER HEATING 
 
VIC 

03 9887 2131 

NSW  

02 9838 0000 

QLD  

07 5597 7360 

 

Factory 6

 

62 Parkhurst Drive 

 

7-9 Activity Crescent

 

 

Knoxfield  VIC  3180 

 

Molendinar 4214

   

 

Victoria Australia   

 

Queensland Australia

 

 

Unit 2 
20-22 Foundry Road, 
Seven Hills 2147 
New South Wales Australia

 

 

 
 
www.sunloversolar.com.au

 

 
 

 

DESCRIPTION: 

The SL6 Elite is a premium automatic solar controller with temperature adjustment, 
manual, winter and tropical mode features. All configurable items are retained after a 
power outage for up to 14 days. 
 

CONTROLLER INSTALLATION: 

Find a suitable location to mount the control box. The controller must be installed out of 

direct weather and no closer than 3 meters from the water’s edge. Lift up the two 
mounting tabs and use two appropriate screws to mount the control box to the wall, 

keeping in mind that the power cable is 1.8m long and should be plugged directly into a 

general power outlet, not into an extension lead. 

The solar pump plugs into the 240Vac socket marked as PUMP. 
The pool sensor must be fitted into the suction line of the pump, as close to the pool as 

practical, preferably in a position out of direct sunlight. It is recommended that a 14.5mm 

hole be drilled in the PVC pipe, this can be carried out using a Dontek PD01 grinding drill 
or a small pilot hole can be drilled and a 14.0mm drill-bit used spinning in a counter 

clockwise direction to minimise the chance of shattering pipe. Insert the grommet into the 

pipe and gently push in the black sensor barb. The green sensor plug is to be fitted to the 
plug socket marked POOL. 

DO NOT cable-tie or tape sensor wires to mains power, in some cases there is some 

benefit to cable tie 30cm of wire from the sensor to the pipe and insulate this section 
(some ambient differences can travel up the tinned copper wire and affect the sensor 

reading). 

Roof sensors must be fitted into a small piece of solar collector or equivalent and attached 
to the roof. The best location is within arm’s length of the gutters edge of the house or 

shed as long as the sensor end is not shaded and is on a roof of similar aspect of the 
main collector. It 

must not 

be fitted on top of the solar collector or fitted to high points 

on the roof like ridge capping as false readings will be detected. 
Keep in mind that it is of the utmost importance to keep the roof sensor as short as 

possible as this will assist in the longevity of the sensor and controller in the event of 
electrical storm activity and power surges. Sensor cables 

must not be run parallel to 

power cables 

and run lengths should be less than 50m if possible. Cable ties should be 

used to fasten the sensor cable to the cold water inlet pipe making sure that the ties are 

approximately 10mm from PVC fittings. Cable ties should be tightened only firm, over 

tightening can cause breaks in the outer PVC if not careful. If the cable is to be run under 
ground a conduit must be used to protect the wire and there is to be no cable joins 
within, conduit ends 

must 

be sealed to prevent water ingress. 

Any excess cable should 

be removed and re-fitted ensuring that the wire ends are tinned with solder. 

The 

sensor plug is to be fitted to the right hand socket marked ROOF.

 

Отзывы: