2-36
Setting Up and Using Laser Alignment Fixtures
Direct Connect (All Models)
Direct Connect is designed for those conditions where it is difficult to communi-
cate between the analyzer and the sensor heads using RF. Conditions such as
building construction materials and contents, other radio systems operating in the
vicinity at or near the same operation frequency, and noise generated by nearby
equipment all may make RF communication unsatisfactory.
Note
Both the A800001 and A821510 Direct Connect cables will work with
the 8215/8225 laser heads for all modes of operation where commu-
nication between the laser heads and analyzer are necessary, except
for the Dual Pass mode. Only the A821510 cable can be used for the
Dual Pass mode when using direct-connect communication.