5-13
If the last segment displayed is not the last measurement location for the moveable
laser head defined, the reference line will extend beyond the last laser head dis-
played to indicate that more measurement locations are defined (as illustrated
above).
Six Measurement locations defined
A graph representing the overall setup is displayed at the bottom of the screen. The
laser heads for the each of the segments defined, including the fixed laser head are
represented on the graph by miniaturized laser fixtures. The positions (segment
lengths) for each of the laser heads will be to scale. The highlighted segment is rep-
resented on the graph by a small arrow centered between the segment’s two laser
heads. The reference line from the location of the fixed laser head is represented
on the graph by a dashed line protruding from the fixed laser head in the direction
(indicated by an arrowhead) of the measurement locations for the moveable laser
head. In the example screen above, a total of six measurement segments have been
defined (represented by miniaturized laser fixtures) and the last (or fifth) segment
field is active (represented by a small arrow).