Horizontal Alignment
Display Sine Fit
From the Sine Fit (Sine Curve Data) plot screen you can review and manually con-
dition or edit the sine curve data. This screen is reached by pressing the Display
Sine Fit key on the tolerance plot screens. This option is available only when the
alignment data was acquired using the Auto Sweep, Dual Pass, or Manual Sweep
methods.
Sine Curve Data Screen
On the sine curve data plot screen, amplitude versus degree data is plotted on the x-y graph.
Amplitude data units will be either in mils or millimeters (mm), depending on the analyzer
units. Active (undeleted) data points (displayed as green triangles are included in the fit cal-
culation while deleted data points (displayed as red diamonds) are excluded from the fit cal-
culation. In addition to the points, the calculated sine curve is displayed.
When a cursor is active, the following alignment data values for the selected point
are displayed just below the plot: