3-78
Horizontal Alignment
Foot Pre-Check Function Keys (prior to starting the Foot Pre-Check)
Start
Use the Start key to start the foot pre-check once you have verified that all hold-
down bolts are tight and positioned the laser heads.
Clear All
Use the Clear All key to clear all acquired data on all feet if data has been acquired
and stored on any foot. Before any data is cleared, a warning message will be dis-
played asking you if this is truly the operation to be performed. If you answer yes,
then the data stored on all of the feet will be cleared. If you answer no the operation
is aborted.
Skip
Use the Skip key to skip the Foot Pre-Check and advance to the data acquisition
screen. Once this option is skipped, it will not be automatically displayed if the
Sweep Laser Heads step is re-entered. The Enter key can be used to do the same.
Set Soft Foot
Use the Set Soft Foot key to change the Foot Pre-Check type to Soft Foot.
Set FDI
Use the Set FDI key to change the Foot Pre-Check type to FDI.
Содержание 2130 RBM Consultant Pro
Страница 1: ...Reference Manual 2130 RBM Consultant Pro Laser Alignment Analyzer and Fixtures Part 97191 Rev 1 ...
Страница 6: ...vi ...
Страница 20: ...1 8 Fixtures Case Layout top section ...
Страница 22: ...2 2 Setting Up and Using Laser Alignment Fixtures Laser heads front view Laser heads rear view ...
Страница 90: ...3 10 Horizontal Alignment ...
Страница 364: ...5 22 Straightness Measurements ...