3-65
Laser Address Selection
When entering any of the machine dimensions, they should be measured and
extended to the nearest 1/8 inch (3 mm). Refer to the Entering Fractions section
on page 3-51 for information about entering fractions.
Refer to the following table for a description of each dimension.
Left and Right Arrow keys
Use the Left and Right Arrow keys to select the field you want to modify (high-
lighted with the red box around it).
Dimension
Measurement Description
Measure
to the
Nearest
U
Diameter of the coupling. This is also, the circumference of
the coupling divided by 3.14 (pi).
1/8 inch
(3 mm)
V
Center of inboard foot on the left machine to the sensor
location on the coupling. This is usually the center of the
coupling.
1/8 inch
(3 mm)
Содержание 2130 RBM Consultant Pro