3-21
Laser Align (Alignment) Method Function Keys
Note
If a lower percentage (smaller valid window) is selected, a slower rota-
tional speed may be required especially with a smaller PSD (e.g. with
the 10x10mm PSD on the 8215). For example, a 10% Target
Window would define a 2mm wide window on an 8225 and a 1mm
wide window on an 8215 centered around the PSD's vertical center-
line in which data will be acquired as the laser beam passes across the
window.
Sample Rate
Use the Sample Rate key, if the alignment method is Manual, Auto 4 Point, or
Manual 4 Point, to set the number of samples (in the range 1 to 25) to be averaged
together to generate a single reading. Two samples (default) are typically sufficient,
but for example, if too much background vibration is present you may want to
increase the number of samples to 25. This option can also be changed after the
job has been created from the Laser Head Status screen.