3-102
Horizontal Alignment
In addition to the green background, the analyzer LED will flash each time a new
reading is measured when the laser heads are within 5° of each other and 3° of the
active cardinal position. If the Status Beeper option located under the 2130 ana-
lyzer’s Home/General Setup screen is enabled you will also hear the analyzer beep
each time a new reading is measured when the laser heads are within 5° of each
other and 3° of the active cardinal position.
If the Status Beeper option located under the 2130 analyzer’s Home/General
Setup screen is disabled the analyzer will not beep when the laser heads are within
5° of each other and 3° of the active cardinal position. In this case only the analyzer
LED will flash as described above.
The current laser reading (in mils or mm, depending on the analyzer units) for
each laser head is displayed in reverse video just below the corresponding angle
position. These readings are continuously averaged whenever the laser heads are at
one of the cardinal positions and automatically recorded when the shaft is rotated
to the next position. The averaging process reduces variation from jitter due to
background vibration or from slight changes in the angular position of the heads.
The traditional cardinal positions (0°, 90°, 180°, and 270°) are displayed graphically
at the bottom of the screen just below the corresponding laser reading. The active
position (highlighted with the red box around it) is the one for which data is being
acquired.
Содержание 2130 RBM Consultant Pro
Страница 1: ...Reference Manual 2130 RBM Consultant Pro Laser Alignment Analyzer and Fixtures Part 97191 Rev 1 ...
Страница 6: ...vi ...
Страница 20: ...1 8 Fixtures Case Layout top section ...
Страница 22: ...2 2 Setting Up and Using Laser Alignment Fixtures Laser heads front view Laser heads rear view ...
Страница 90: ...3 10 Horizontal Alignment ...
Страница 364: ...5 22 Straightness Measurements ...