3-57
Laser Address Selection
Growth at Feet
If Thermal Growth at Feet has been defined as the thermal growth method for the
job, you are able to input the amount of vertical and horizontal thermal growth at
each machine foot.
Enter Growth at Feet
Growth in the vertical direction is displayed in the upper section of the screen while
growth in the horizontal direction is displayed in the lower section of the screen.
The amount of vertical thermal growth that both machines will experience during
operation can be expressed in either mils or millimeters (mm), depending on the
analyzer units. Thermal growth values should correspond to the amount each shaft
moves in the vertical and horizontal directions directly above each foot. If thermal
growth is negligible, either leave it blank or enter zeroes. At least one non-zero value
must be entered before continuing. The range of values that can be entered for the
vertical direction are -250 to 250 mils or -6.35 to 6.35 mm. The range of values that
can be entered for the horizontal direction are -250 to 250 mils or -6.35 to 6.35 mm.