4-32
Vertical Alignment
Review Results key
Use the Review Results key on the Alt screen to return to the Review Measurements
screen where you can continue reviewing and averaging together the results from
multiple acquisitions. This key is available only when the Review Results option is
enabled on the Alt Main screen and the Review Measurements screen has been
exited before the averaged reading set was saved. Refer to the Vertical Review
Results section on page 4-37 for more information.
Acquiring data using Manual Sweep
Accept Readings key
Use the Accept Readings key to store the data when the laser head positions and
data are as desired. The number of samples, displayed in the top of the screen just
above the flange graphics, will increment by one (180 max). Each time a data point
is stored and the laser heads are rotated to a new position, a thin black line is left
behind to denote where data was acquired.