3-105
Laser Address Selection
If the data validity is unsatisfactory a warning message displays to inform you that an
unsatisfactory data validity condition exists. At this point you should repeat the data
acquisition. This built-in check helps alert you to the data losing reliability in the
misalignment calculations.
Note
For the greatest accuracy and repeatability, all readings should be
acquired using the same direction of rotation. In addition, it is best to
rotate the heads in the same direction the machine rotates when run-
ning.
Note
Remember, when shaft movement due to factors other than misalignment is
present in the data, this will appear as randomness (noise) in the data. This is
not normally a problem when the misalignment is great, but will increas-
ingly interfere as the misalignment decreases. Therefore, the better the align-
ment the more likely the chance will be of getting a data validity warning.
Manual 4 Point
If Manual 4 Point has been defined as the laser alignment method for the job, the
user has complete control over when data is acquired and which of the four mea-
surement positions data is to be acquired in. This method is useful when the
machinery is not mounted in a true horizontal orientation, so that the inclinom-
eter is not effective, or when the clock positions relative to vertical and horizontal
base movements of the machine are nonstandard. This method is similar to Auto
4 Point except in this method data is manually acquired and stored in the Laser
Align program. Also, readings are not continuously averaged whenever the laser
heads are at one of the cardinal positions.
Note
Both laser heads need to be turned on for this option to function
properly.
Содержание 2130 RBM Consultant Pro
Страница 1: ...Reference Manual 2130 RBM Consultant Pro Laser Alignment Analyzer and Fixtures Part 97191 Rev 1 ...
Страница 6: ...vi ...
Страница 20: ...1 8 Fixtures Case Layout top section ...
Страница 22: ...2 2 Setting Up and Using Laser Alignment Fixtures Laser heads front view Laser heads rear view ...
Страница 90: ...3 10 Horizontal Alignment ...
Страница 364: ...5 22 Straightness Measurements ...