3-110
Horizontal Alignment
Enter key
Use the Enter key to accept the data, after you have acquired it. At this point the
data is checked for validity. Refer to the Data Quality section on page 3-127 for
more information.
If the data validity is satisfactory, and Review Results is enabled on the Alt Main
screen, the software displays the Review Measurements screen. If data validity is sat-
isfactory and Review Results is not enabled, the program will mark the Sweep Laser
Heads step back on the Main screen completed and advance you to the next step
in the procedure. In addition to marking the Sweep Laser Heads step complete,
the number of moves displayed in the upper section of the main screen is updated.
If the data validity is unsatisfactory a warning message displays to inform that an
unsatisfactory data validity condition exists. At this point you should repeat the data
acquisition. This built-in check helps alert you to a problem with the reliability of
the collected data.
Note
For the greatest accuracy and repeatability, all readings should be
acquired using the same direction of rotation. In addition, it is best to
rotate the lasers in the same direction the machine rotates when run-
ning.
Note
Remember, when shaft movement due to causes other than misalignment is
present in the data, this will appear as randomness (noise) in the data. This is
not normally a problem when the misalignment is great, but will increas-
ingly interfere as the misalignment decreases. Therefore, the better the align-
ment the more likely the chance will be of getting a data validity warning.
Содержание 2130 RBM Consultant Pro
Страница 1: ...Reference Manual 2130 RBM Consultant Pro Laser Alignment Analyzer and Fixtures Part 97191 Rev 1 ...
Страница 6: ...vi ...
Страница 20: ...1 8 Fixtures Case Layout top section ...
Страница 22: ...2 2 Setting Up and Using Laser Alignment Fixtures Laser heads front view Laser heads rear view ...
Страница 90: ...3 10 Horizontal Alignment ...
Страница 364: ...5 22 Straightness Measurements ...