3-66
Horizontal Alignment
Enter key
Use the Enter key to advance to the Enter Gap/Offset Target screen.
Enter Gap/Offset Target
The Enter Gap/Offset Target screen, allows you to enter the gap and offset
thermal growth target numbers at the coupling.
Growth in the vertical direction is displayed in the upper section of the screen while
growth in the horizontal direction is displayed in the lower section of the screen.
The amount of thermal growth that both machines will experience during opera-
tion can be expressed in either mils or millimeters (mm), depending on the ana-
lyzer units. If thermal growth is negligible, either leave it blank or enter zeroes. At
least one non-zero value must be entered before continuing. The range of values
that can be entered for both the gap and offset are 0 to 2048 mils or 0 to 52.02 mm.
Gap is the difference in the coupling halves at the top and at the bottom at the spec-
ified diameter. If the number is greater at the top, the gap is considered to be
“open” on the top. If the number is greater at the bottom, the gap is considered to
be “open” on the bottom.