3-28
Horizontal Alignment
Read Head A Address key
Use the Read Head A Address key to read and set the address in Head A. To read
and set the laser head addresses the direct connect cable must be attached to each
of the laser heads and the analyzer first before this option is selected. After the
direct connect cable is attached, turn Head A on and leave Head B turned off.
Received Address Subwindow
When the Received Address subwindow is displayed the actual address setup in
Head A also displays. If the address is not correct or you wish to change it, type in
the new address from 1 (default) to 10, then press the Enter key to accept the
change and return to the Current Addresses screen. The new address must be dif-
ferent than the Head B address. If the address is correct, press Enter to return to
the Current Addresses screen.
Caution!
When connecting any device to the RS232 serial port located on the top panel of
the analyzer, the analyzer must be turned off.