3-101
Laser Address Selection
Note
When using the Auto 4 Point method, an alternative option to
increasing the number of samples (or increasing the data averaging
beyond 25 samples per reading), would be to stop the laser fixtures at
each of the four clock positions and allow the program to continu-
ously average the data.
Starting Auto 4 Point
On the data acquisition screen for Auto 4 Point, the current angle position for each
laser head is displayed just below the corresponding machine. The background
area of the angle position is white if the laser heads are not within 5° of each other
and 3° of the active cardinal position. The background area of the angle position is
green if the laser heads are within 5° of each other and 3° of the active cardinal posi-
tion.