3-73
Laser Address Selection
When entering any of the machine dimensions, they should be measured and
extended to the nearest 1/16 inch (1.5 mm). Refer to the Entering Fractions sec-
tion on page 3-51 for information about entering fractions.
Refer to the following table for a description of each dimension.
Left and Right Arrow keys
Use the Left and Right Arrow keys to select the field you want to modify (high-
lighted with the red box around it).
Dimension
Measurement Description
Measure
to the
Nearest
M
Center of inboard foot on the left machine to the sensor location
on the left machine shaft.
1/16 inch
(1.5 mm)
N
Sensor location on the left machine shaft across the coupling to
the sensor location on the right machine shaft.
1/16 inch
(1.5 mm)
Содержание 2130 RBM Consultant Pro
Страница 1: ...Reference Manual 2130 RBM Consultant Pro Laser Alignment Analyzer and Fixtures Part 97191 Rev 1 ...
Страница 6: ...vi ...
Страница 20: ...1 8 Fixtures Case Layout top section ...
Страница 22: ...2 2 Setting Up and Using Laser Alignment Fixtures Laser heads front view Laser heads rear view ...
Страница 90: ...3 10 Horizontal Alignment ...
Страница 364: ...5 22 Straightness Measurements ...