3-95
Laser Address Selection
Note
Both laser heads need to be turned on for this option to function
properly.
When setting the job up to use Manual Sweep as the Laser Align Method for
acquiring data, you must also select the acquisition mode to be either Standard or
Averaging and set the sample rate. The sample rate determines the number of data
samples that are to be collected and averaged together to produce a single Laser
PSD reading.
Standard Mode
This mode of operation is the mode that is most often used during Manual Sweep
alignments. In the Standard mode, data acquired in the data acquisition’s direction
of rotation will always overwrite any previous data stored at the same angular posi-
tion.
Содержание 2130 RBM Consultant Pro