3-89
Laser Address Selection
Positioning heads for Auto Sweep
The first data acquisition screen for Auto Sweep, prompts you to turn on and posi-
tion the laser heads at the starting angle.
For this method, the position of the laser heads can be at any angular position you
desire to start from. It is not required to define a sweep arc range and direction of
rotation due to the increased number of data readings acquired every 2° and the
process, which automatically defines the direction of rotation.
The current laser head position (represented by a hash mark on the outer most
part of the circle) is displayed graphically at the bottom of the screen. The average
angle reading will be displayed within the circle. The background of the circle will
be white if the laser heads are not within 2° of each other and green when the laser
heads are within 2° of each other.
Initialize Lasers key
Use the Initialize Lasers key to initialize the laser heads and advance to the next step
in the procedure. The Enter key can be used to do the same.