3-81
Laser Address Selection
Note
Both the Soft Foot and FDI tolerance values can be changed in
UltraMgr and transferred to the Advanced Laser Align program.
Warning!
The numbers displayed are not the required correction shims for this
foot. Soft Foot and FDI corrections frequently require wedge shaped
arrangements of shims to be installed. However, the actual thickness
and shape of the Soft Foot and FDI correction must be determined
by using a feeler gauge.
Enter key
Use the Enter key to accept and store the reading for the active foot. The Accept
key can be used to do the same.