3-72
Horizontal Alignment
Reverse Dial
If Reverse Dial has been defined as the thermal growth method for the job, you are
able to input the amount of vertical and horizontal thermal growth using target
reverse dial indicator readings. The program will then use this information to cal-
culate the vertical and horizontal thermal growth at each machine foot. This
method consists of the following three screens.
Enter Reverse Dial Dimensions
The Enter Reverse Dial Dimensions screen, allows you to enter the dimensions for
the sensor locations and their relationship with respect to the machine feet loca-
tions as defined in the Enter Dimensions screen.
Dimensions can be expressed in either inches or millimeters (mm), depending on
the analyzer units. All dimensions must be entered before continuing. The range
of values that can be entered for the M dimension are -3600 to 3600 inches or
-91440 to 91440 mm. The range of values that can be entered for the N dimension
are 0.01 to 3600 inches or 0.254 to 91440 mm.