3-79
Laser Address Selection
Check Lasers
Use the Check Lasers key to check the operational status of the heads. Refer to the
Check Lasers section on page 3-30 for more information.
Performing a Foot Pre-Check
Once the Foot Pre-Check starts, a prompt displays as notification to loosen the hold-
down bolt for the selected foot and wait for the data to stabilize. The arrow displays
within the circle at the bottom of the screen and assists in determining data stability.
When data is unstable, the arrow turns (rotates). When data is stable, the arrow
stops turning.
Once the arrow stops turning, accept the reading and either select another foot or
advance beyond the Foot Pre-Check. After accepting a reading, it is evaluated based
on the type of Foot Pre-Check being used.
Caution!
Be sure to retighten the bolt after you have accepted the reading for that foot before
starting another check or acquiring any alignment data.