3-106
Horizontal Alignment
When setting the job up to use Manual 4 Point as the Laser Align Method for
acquiring data, you must also set the sample rate. The sample rate determines the
number of data samples that are to be collected and averaged together to produce
a single Laser PSD reading.
Starting Manual 4 Point
On the data acquisition screen for Manual 4 Point, the current angle position for
each laser head is displayed just below the corresponding machine. The back-
ground area of the angle position will be white if the laser heads are not within 5°
of each other and 3° of the active cardinal position. The background area of the
angle position will be green if the laser heads are within 5° of each other and 3° of
the active cardinal position.
In Manual 4 Point, the analyzer LED and beeper are not active when the laser
heads are within 5° of each other and 3° of the active cardinal position as it is in
Auto 4 Point.
Содержание 2130 RBM Consultant Pro
Страница 1: ...Reference Manual 2130 RBM Consultant Pro Laser Alignment Analyzer and Fixtures Part 97191 Rev 1 ...
Страница 6: ...vi ...
Страница 20: ...1 8 Fixtures Case Layout top section ...
Страница 22: ...2 2 Setting Up and Using Laser Alignment Fixtures Laser heads front view Laser heads rear view ...
Страница 90: ...3 10 Horizontal Alignment ...
Страница 364: ...5 22 Straightness Measurements ...