4-2
Vertical Alignment
Measurements should be taken with the laser system set up across the coupling to
determine the offset and angle between the two shafts. Correct the angle by shim-
ming in the vertical direction. The offset is corrected by sliding the machine at the
flange.
Mounting Fixtures
Mount the fixtures as pictured in the figure below. It does not matter which head is
on top; this will be configured in the analyzer. For applications with tight mounting
requirements, use thin brackets (P/N 8AA54 or 8AA55). RF or direct connect data
communication to the analyzer can be used.
Note
Because of the orientation of the laser heads gravity is not working on
the sensitive axis. Therefore, the angle sensors cannot measure the
rotational position.