3-165
Laser Address Selection
For all plot types
•
Alignment reading sets will be plotted on the x-y graph with lines connecting each
of the data points for a given direction. Vertical data points display in blue while hor-
izontal data points display in red.
•
Depending on the tolerance type defined for the job and the analyzer units, align-
ment angle data will be either in mils/inch or milliradian (mrad) while offset data
will be either in mils or millimeters (mm).
•
The area under the lowest arc is the excellent range. The area under the higher arc
and above the lower arc represents the acceptable range. Refer to the Tolerances
section on page 3-193 for more information.
•
When the cursor is active, the calculated alignment data values for the selected
point are displayed at the bottom of the screen.
•
The RPM defined for the job is displayed just to the right of the calculated align-
ment data values.
Up and Down Arrow keys
Use the Up and Down Arrow keys to expand and compress (contract) the Y Axis
by a factor of two.
Left and Right Arrow keys
Use the Left and Right Arrow keys to move the cursor between the data points.
Enter key
Use the Enter key to return to the screen from which this option was selected.