Troubleshooting the Tape Library
•
Self test failed
– Inspect the module connectors and module-to-module cables for bent or
broken pins. Contact service to order replacement cable or expansion module.
•
Self test passed
– Power cycle the library to allow for a final termination and connectivity
check.
Select
Continue
before you turn off the library power.
3
The library determined that the problem is corrected. The RAS ticket will be closed.
DR011 - Resolve I/E Station Lock/Unlock Failure
This DR provides customer resolution steps for:
•
T031
on page 229
•
T032
on page 230
Problem: An I/E station lock failed to operate properly. It is possible for a user to interfere with lock and
unlock operations by trying to open/close an I/E station door while the lock is attempting to engage or
disengage.
1
If the user opened or closed the I/E station at the time the problem was reported, close this RAS ticket
and retry operations.
2
If there was no user interaction with the I/E station at the time the problem was reported, defective
hardware is likely.
3
If the issue re-occurs, contact Service to resolve the problem.
4
You have three options:
a. Select
Close
to close the ticket now.
b. Select
Exit
to leave the ticket open for future troubleshooting.
c. Select
Back
to return to the Diagnostic Resolution.
DR012 - Resolve Drive TapeAlert 32 - Host Interface
This DR provides customer resolution steps for
T051
on page 248.
Problem: A tape drive has detected and reported a problem with its host interface connection. This can be
caused by a loose or disconnected cable, bad termination, or other FC, SAS, or SCSI communication
issues.
1
If the drive is a SCSI drive:
•
Check for proper termination.
•
Check whether the cable length meets SCSI limits.
•
Check host and drive connectors for bent or broken pins.
•
Secure host and drive connectors,
2
If the drive is a SAS or Fibre Channel drive:
•
Check that cable connections are secure.
•
Check for broken or pinched cables.
•
Check for cable bend radius being too tight.
•
Check that cable connections are clean.
3
Check that all hardware components between the host and drive are communicating correctly.
Содержание PowerVault ML6000
Страница 1: ...w w w d e l l c o m s u p p o r t d e l l c o m MaintenanceGuide Dell PowerVault ML6000 ...
Страница 14: ...xiv Tables ...
Страница 18: ...xviii Figures ...
Страница 452: ...434 Troubleshooting the Tape Library ...
Страница 456: ...438 Library Drawings Library Rear View Figure 32 ML6020 Rear View ...
Страница 463: ...PowerVault ML6000 Maintenance Guide 445 Figure 42 Model 1 Picker Assembly Figure 43 Model 2 Picker Assembly ...
Страница 466: ...448 Library Drawings Figure 46 Model 1 Parking Tab Parked Figure 47 Model 2 Parking Tab Parked ...
Страница 467: ...PowerVault ML6000 Maintenance Guide 449 Library Control Blade LCB Figure 48 Library Control Blade ...
Страница 468: ...450 Library Drawings Power Supplies Figure 49 Power Supplies ...
Страница 475: ...PowerVault ML6000 Maintenance Guide 457 Rack mounted Library Figure 56 Rack mounted Library Front ...
Страница 477: ...PowerVault ML6000 Maintenance Guide 459 Figure 58 Electrical System 5U Library Control Module ...
Страница 478: ...460 Library Drawings Figure 59 LCB Functions ...
Страница 479: ...PowerVault ML6000 Maintenance Guide 461 ...
Страница 480: ...462 Library Drawings Figure 60 Accessor Control Block Figure 61 Door and Import Export Board DIEB ...
Страница 481: ...PowerVault ML6000 Maintenance Guide 463 Figure 62 Door and Display Block Figure 63 Power System Block ...
Страница 482: ...464 Library Drawings Figure 64 Fan Control Board ...
Страница 483: ...PowerVault ML6000 Maintenance Guide 465 Figure 65 Library Cables ...
Страница 484: ...466 Library Drawings Figure 66 Library System Grounding ...
Страница 485: ...PowerVault ML6000 Maintenance Guide 467 Figure 67 Library Power System ...
Страница 486: ...468 Library Drawings ...
Страница 494: ...476 Glossary Y axis Y position The vertical position of the library s robotic arm ...