PowerVault ML6000 Maintenance Guide
409
DR094 - Resolve Drive Power Fuse Failure
This DR provides resolution steps for
T066
on page 264.
Problem: A problem has been detected and isolated to a fuse that protects a tape drive power circuit. The
fuse is blown and requires replacement. The blown fuse may have been caused by a defective drive or
some other failed hardware.
Users should contact Service to replace the fuse. Note that you must shut down the library and disconnect
the library power completely before replacing the fuse.
1
View the ticket details to determine in which module the blown fuse is located.
2
Contact Service to obtain and replace the fuse (see
Removing and Replacing the Drive Power Fuse
on
page 148).
3
Close the ticket.
4
Shut down the library and disconnect the library power completely before replacing the fuse.
5
Power up the library. Did the new fuse blow and create a ticket? If NOT, the problem was likely a weak
or defective fuse. Monitor for recurrence.
6
If the new fuse DID blow, close the ticket, shut down the library, disconnect the library power, remove
all the drives in the module, and replace the fuse again.
7
Power up the library. Did the fuse blow again? If YES, the problem is isolated to the module. The module
must be replaced.
8
If the new fuse DID NOT blow, install drive sleds one at a time. Check for this ticket after each drive sled
installation to determine which drive sled is causing the fuse to blow.
9
You have three options:
a. Select
Close
to close the ticket now.
b. Select
Exit
to leave the ticket open for future troubleshooting.
c. Select
Back
to return to the Diagnostic Resolution.
DR095 - Resolve Drive Sled Auto-Level Failure
This DR provides customer resolution steps for
T129
on page 328.
Problem: The library is not able to auto-level any of the drive sleds. This problem may be caused by a
missing or corrupt firmware update image file.
1
Close this ticket and perform a library firmware upgrade to the current production firmware revision.
2
If this ticket reoccurs following the library firmware upgrade, contact Service for additional diagnostic
steps.
3
You have three options:
a. Select
Close
to close the ticket now.
b. Select
Exit
to leave the ticket open for future troubleshooting.
c. Select
Back
to return to the Diagnostic Resolution.
DR096 - Resolve Drive Cleaning Failure
This DR provides customer resolution steps for
T130
on page 329.
Problem: After the tape drive was cleaned and the cleaning tape cartridge was removed from the tape drive,
the tape drive continues to request drive cleaning. This could indicate a problem with the tape drive.
Содержание PowerVault ML6000
Страница 1: ...w w w d e l l c o m s u p p o r t d e l l c o m MaintenanceGuide Dell PowerVault ML6000 ...
Страница 14: ...xiv Tables ...
Страница 18: ...xviii Figures ...
Страница 452: ...434 Troubleshooting the Tape Library ...
Страница 456: ...438 Library Drawings Library Rear View Figure 32 ML6020 Rear View ...
Страница 463: ...PowerVault ML6000 Maintenance Guide 445 Figure 42 Model 1 Picker Assembly Figure 43 Model 2 Picker Assembly ...
Страница 466: ...448 Library Drawings Figure 46 Model 1 Parking Tab Parked Figure 47 Model 2 Parking Tab Parked ...
Страница 467: ...PowerVault ML6000 Maintenance Guide 449 Library Control Blade LCB Figure 48 Library Control Blade ...
Страница 468: ...450 Library Drawings Power Supplies Figure 49 Power Supplies ...
Страница 475: ...PowerVault ML6000 Maintenance Guide 457 Rack mounted Library Figure 56 Rack mounted Library Front ...
Страница 477: ...PowerVault ML6000 Maintenance Guide 459 Figure 58 Electrical System 5U Library Control Module ...
Страница 478: ...460 Library Drawings Figure 59 LCB Functions ...
Страница 479: ...PowerVault ML6000 Maintenance Guide 461 ...
Страница 480: ...462 Library Drawings Figure 60 Accessor Control Block Figure 61 Door and Import Export Board DIEB ...
Страница 481: ...PowerVault ML6000 Maintenance Guide 463 Figure 62 Door and Display Block Figure 63 Power System Block ...
Страница 482: ...464 Library Drawings Figure 64 Fan Control Board ...
Страница 483: ...PowerVault ML6000 Maintenance Guide 465 Figure 65 Library Cables ...
Страница 484: ...466 Library Drawings Figure 66 Library System Grounding ...
Страница 485: ...PowerVault ML6000 Maintenance Guide 467 Figure 67 Library Power System ...
Страница 486: ...468 Library Drawings ...
Страница 494: ...476 Glossary Y axis Y position The vertical position of the library s robotic arm ...