408
Troubleshooting the Tape Library
5
You have three options:
a. Select
Close
to close the ticket now.
b. Select
Exit
to leave the ticket open for future troubleshooting.
c. Select
Back
to return to the Diagnostic Resolution.
DR093 - Resolve Robotics Communication Error
This DR provides customer resolution steps for:
•
T127
on page 326
•
T139
on page 338
Problem: The library firmware did establish communication with the robotics subsystem, but encountered a
communication failure during operation. This problem may be caused by one or more of the following
conditions:
•
Power loss to the robot assembly.
•
Cable spool or connection failure.
•
Electrical hardware failure.
1
Check if other tickets exist that may identify a power or robot initialization error, and resolve such tickets
before continuing to the next step.
2
Check if the picker assembly is powered, by opening and looking through an I/E station closest to the
robot position to determine whether the green picker assembly LED is lit or blinking.
3
If the LED is OFF, continue as follows:
a. Check that the module terminators are fully connected and secured, and that all main access
doors are fully closed.
b. If terminators are secured and main doors are closed, open and close each main access door
one by one, and observe if the robot initializes after the doors are closed.
c. If the robot initializes, close the previously opened I/E station and observe whether the robot
scans the I/E elements.
d. If the I/E station scan succeeds, the issue is resolved; close this ticket and continue operation.
4
If the previous step did not resolve the issue, or the LED is ON, close this ticket, power off the library,
and continue as follows:
a. Remove and inspect both module terminators and connectors for pin damage, then reattach
and secure.
b. If the library consists of multiple library modules, remove and inspect all module-to-module
cables and connectors for pin damage, then reattach and secure.
c. Open the library's main doors; inspect the cable spool for visible damage, and ensure that it is
properly connected and secured at the robot assembly's J1 hook connector.
d. Close all main doors, power up the library, and observe library initialization.
5
If no issue was found, and this ticket reoccurs, contact Service for assistance.
6
You have three options:
a. Select
Close
to close the ticket now.
b. Select
Exit
to leave the ticket open for future troubleshooting.
c. Select
Back
to return to the Diagnostic Resolution.
Содержание PowerVault ML6000
Страница 1: ...w w w d e l l c o m s u p p o r t d e l l c o m MaintenanceGuide Dell PowerVault ML6000 ...
Страница 14: ...xiv Tables ...
Страница 18: ...xviii Figures ...
Страница 452: ...434 Troubleshooting the Tape Library ...
Страница 456: ...438 Library Drawings Library Rear View Figure 32 ML6020 Rear View ...
Страница 463: ...PowerVault ML6000 Maintenance Guide 445 Figure 42 Model 1 Picker Assembly Figure 43 Model 2 Picker Assembly ...
Страница 466: ...448 Library Drawings Figure 46 Model 1 Parking Tab Parked Figure 47 Model 2 Parking Tab Parked ...
Страница 467: ...PowerVault ML6000 Maintenance Guide 449 Library Control Blade LCB Figure 48 Library Control Blade ...
Страница 468: ...450 Library Drawings Power Supplies Figure 49 Power Supplies ...
Страница 475: ...PowerVault ML6000 Maintenance Guide 457 Rack mounted Library Figure 56 Rack mounted Library Front ...
Страница 477: ...PowerVault ML6000 Maintenance Guide 459 Figure 58 Electrical System 5U Library Control Module ...
Страница 478: ...460 Library Drawings Figure 59 LCB Functions ...
Страница 479: ...PowerVault ML6000 Maintenance Guide 461 ...
Страница 480: ...462 Library Drawings Figure 60 Accessor Control Block Figure 61 Door and Import Export Board DIEB ...
Страница 481: ...PowerVault ML6000 Maintenance Guide 463 Figure 62 Door and Display Block Figure 63 Power System Block ...
Страница 482: ...464 Library Drawings Figure 64 Fan Control Board ...
Страница 483: ...PowerVault ML6000 Maintenance Guide 465 Figure 65 Library Cables ...
Страница 484: ...466 Library Drawings Figure 66 Library System Grounding ...
Страница 485: ...PowerVault ML6000 Maintenance Guide 467 Figure 67 Library Power System ...
Страница 486: ...468 Library Drawings ...
Страница 494: ...476 Glossary Y axis Y position The vertical position of the library s robotic arm ...