PowerVault ML6000 Maintenance Guide
225
T027
T027 - Key Server Request Failure
Description
GUI Description:
The library is unable to receive a proper response to a key
server request.
Explanation:
The key management feature of the library allows the user to
connect two key servers for redundancy. If a server request to one of these
servers fails and a communication failover is not possible or not successful,
this RAS ticket will be generated. A separate RAS ticket will be created for
each key server that fails.
Detection Scenarios
• Library detects that communication with a key server is not successful and
a communication failover is not possible.
• Library detects that the key server is not properly configured.
Root Causes
• Primary/secondary key server is not connected properly.
• Primary/secondary key server is not configured properly.
• Library Ethernet settings are not configured properly.
• Key server is not configured/restored correctly.
Service Resolution
Steps
1 Perform
DR079 - Resolve Key Server Request Issue
on page 401/
2 Perform EKM Path Diagnostics (
Tools > Diagnostics > EKM > EKM Path
Diagnostics
in the Web client). See
Running EKM Path Diagnostics
on
page 8.
3 If the “Ping” test is unsuccessful, look for physical connection problems and
down server(s).
4 If “Ping” is successful, do the following:
a. Verify that EKM
is running.
b. Verify that the media is not from a different
EKM
environment.
c. Verify that the key server is present.
Possible CRUs/FRUs
None
Содержание PowerVault ML6000
Страница 1: ...w w w d e l l c o m s u p p o r t d e l l c o m MaintenanceGuide Dell PowerVault ML6000 ...
Страница 14: ...xiv Tables ...
Страница 18: ...xviii Figures ...
Страница 452: ...434 Troubleshooting the Tape Library ...
Страница 456: ...438 Library Drawings Library Rear View Figure 32 ML6020 Rear View ...
Страница 463: ...PowerVault ML6000 Maintenance Guide 445 Figure 42 Model 1 Picker Assembly Figure 43 Model 2 Picker Assembly ...
Страница 466: ...448 Library Drawings Figure 46 Model 1 Parking Tab Parked Figure 47 Model 2 Parking Tab Parked ...
Страница 467: ...PowerVault ML6000 Maintenance Guide 449 Library Control Blade LCB Figure 48 Library Control Blade ...
Страница 468: ...450 Library Drawings Power Supplies Figure 49 Power Supplies ...
Страница 475: ...PowerVault ML6000 Maintenance Guide 457 Rack mounted Library Figure 56 Rack mounted Library Front ...
Страница 477: ...PowerVault ML6000 Maintenance Guide 459 Figure 58 Electrical System 5U Library Control Module ...
Страница 478: ...460 Library Drawings Figure 59 LCB Functions ...
Страница 479: ...PowerVault ML6000 Maintenance Guide 461 ...
Страница 480: ...462 Library Drawings Figure 60 Accessor Control Block Figure 61 Door and Import Export Board DIEB ...
Страница 481: ...PowerVault ML6000 Maintenance Guide 463 Figure 62 Door and Display Block Figure 63 Power System Block ...
Страница 482: ...464 Library Drawings Figure 64 Fan Control Board ...
Страница 483: ...PowerVault ML6000 Maintenance Guide 465 Figure 65 Library Cables ...
Страница 484: ...466 Library Drawings Figure 66 Library System Grounding ...
Страница 485: ...PowerVault ML6000 Maintenance Guide 467 Figure 67 Library Power System ...
Страница 486: ...468 Library Drawings ...
Страница 494: ...476 Glossary Y axis Y position The vertical position of the library s robotic arm ...