PowerVault ML6000 Maintenance Guide
59
Preparing to Install an Additional 9U Expansion Module
Required tools:
•
Phillips #2 screwdriver, for removing and replacing the top cover plate
•
T10 TORX screwdriver, for removing and replacing the bottom cover plate
You need to unstack the library to install the new 9U Expansion Module expansion module at the bottom of
the new library configuration.
1
Upgrade the library firmware to a level that can support the number of modules you are adding.
2
If you have a partition that spans modules, and you plan to add the new 9U Library Expansion Module
between those modules, you must delete the partition before adding the new module.
3
Remove all tape cartridges from the library, using the import and export commands of the operator
panel or Web client.
4
Power off the library.
5
Disconnect all power cords, network data cables, and module-to-module cables from all of the modules.
6
Park the robot assembly in the 5U Library Control Module. Before unstacking the library, the robot
assembly must be placed in the 5U Library Control Module.
a. Open the I/E station and access doors of each module.
b. Using your hands, gently lift the robot assembly into the 5U Library Control Module. The robot
assembly should glide slowly and with some resistance.
WARNING
WITHOUT TAPE DRIVES, TAPE CARTRIDGES, OR POWER
SUPPLIES, A 5U LIBRARY CONTROL MODULE WEIGHS
APPROXIMATELY 60 LBS (27.2 KG). A 9U EXPANSION MODULE,
WITHOUT TAPE DRIVES, TAPE CARTRIDGES, OR POWER
SUPPLIES, EXCEEDS 65 LBS (29.5 KG).
TO AVOID SERIOUS INJURY, AT LEAST TWO PEOPLE ARE
REQUIRED TO SAFELY LIFT THE MODULES INTO POSITION.
CAUTION
If the library contains a partition that spans modules, and you plan to
install the new 9U Library Expansion Module between those modules,
you must delete the partition before adding the new module, and re-
create the partition after installing the module.
Note
Label all cables before you remove them, so you can later reconnect them
to their proper locations.
CAUTION
Support the robot assembly by holding onto the broad metal X-axis
base plate. Lifting the robot by the thin metal rod will bend the rod.
Lifting the robot by the black plastic picker body can damage the
robot.
For information on updating firmware, see the
Dell PowerVault ML6000 Tape Library User’s Guide
.
Содержание PowerVault ML6000
Страница 1: ...w w w d e l l c o m s u p p o r t d e l l c o m MaintenanceGuide Dell PowerVault ML6000 ...
Страница 14: ...xiv Tables ...
Страница 18: ...xviii Figures ...
Страница 452: ...434 Troubleshooting the Tape Library ...
Страница 456: ...438 Library Drawings Library Rear View Figure 32 ML6020 Rear View ...
Страница 463: ...PowerVault ML6000 Maintenance Guide 445 Figure 42 Model 1 Picker Assembly Figure 43 Model 2 Picker Assembly ...
Страница 466: ...448 Library Drawings Figure 46 Model 1 Parking Tab Parked Figure 47 Model 2 Parking Tab Parked ...
Страница 467: ...PowerVault ML6000 Maintenance Guide 449 Library Control Blade LCB Figure 48 Library Control Blade ...
Страница 468: ...450 Library Drawings Power Supplies Figure 49 Power Supplies ...
Страница 475: ...PowerVault ML6000 Maintenance Guide 457 Rack mounted Library Figure 56 Rack mounted Library Front ...
Страница 477: ...PowerVault ML6000 Maintenance Guide 459 Figure 58 Electrical System 5U Library Control Module ...
Страница 478: ...460 Library Drawings Figure 59 LCB Functions ...
Страница 479: ...PowerVault ML6000 Maintenance Guide 461 ...
Страница 480: ...462 Library Drawings Figure 60 Accessor Control Block Figure 61 Door and Import Export Board DIEB ...
Страница 481: ...PowerVault ML6000 Maintenance Guide 463 Figure 62 Door and Display Block Figure 63 Power System Block ...
Страница 482: ...464 Library Drawings Figure 64 Fan Control Board ...
Страница 483: ...PowerVault ML6000 Maintenance Guide 465 Figure 65 Library Cables ...
Страница 484: ...466 Library Drawings Figure 66 Library System Grounding ...
Страница 485: ...PowerVault ML6000 Maintenance Guide 467 Figure 67 Library Power System ...
Страница 486: ...468 Library Drawings ...
Страница 494: ...476 Glossary Y axis Y position The vertical position of the library s robotic arm ...