PowerVault ML6000 Maintenance Guide
381
8
If the tickets do reappear, contact Service for CAN bus terminator and module-to-module cable
replacement. Close all
T021 - Drive Sled Communication Failure
tickets and power down the library.
Replace the terminators and cables and restart the library.
9
If the tickets continue to reappear contact Service and request a library controller blade (LCB)
replacement if no drives are communicating, or a module replacement if drives in the control module
are operational, but communication in extension modules is failing. (Replace the CM prior to any EM,
no matter of T021 drive location.)
10
You have three options:
a. Select
Close
to close the ticket now.
b. Select
Exit
to leave the ticket open for future troubleshooting.
c. Select
Back
to return to the Diagnostic Resolution.
DR030 - Resolve Drive Load Failure
This DR provides customer resolution steps for
T009
on page 205.
Problem: The robot was unable to load a tape cartridge into a drive. The robot motion completed normally,
but the tape drive did not report that it successfully loaded the tape cartridge. The problem may be caused
by defective drive hardware, or a defective picker mechanism.
1
The problem is most likely isolated to the specific tape drive referenced in the ticket details. However,
check for the same problem being reported for other tape drives in the system.
2
If this same problem is reported for multiple tape drives, contact Service for a picker assembly
replacement.
3
If this problem is isolated to an individual tape drive, contact Service for drive sled replacement.
4
You have three options:
a. Select
Close
to close the ticket now.
b. Select
Exit
to leave the ticket open for future troubleshooting.
c. Select
Back
to return to the Diagnostic Resolution.
DR031 - Resolve Robot Initialization Failure
This DR provides resolution steps for
T076
on page 274.
Problem: During power-up, or after closing the library main access doors, the robot did not initialize properly.
A common cause for this problem is an unplugged cable that leads to the robot assembly or the 5U Library
Control Module. Other permanent hardware failures that result in loss of connection to the robot can also
be a root cause.
1
Open the library main access doors. This will allow access to the robot and remove power from the
robot.
2
Check for any obvious disconnected cables leading to the robot.
3
Remove the drives from the 5U Library Control Module.
4
Check for any loose cable connections on the circuit board behind the lower drive.
5
If any disconnected cables are discovered, plug them in and close all main access doors. The robot
automatically attempts to initialize.
6
Power off the library and inspect all terminators and module-to-module cables for bent or broken pins.
Contact service to replace any damaged parts.
7
If no problem is found, or the robot continues to fail, contact Service for assistance.
Содержание PowerVault ML6000
Страница 1: ...w w w d e l l c o m s u p p o r t d e l l c o m MaintenanceGuide Dell PowerVault ML6000 ...
Страница 14: ...xiv Tables ...
Страница 18: ...xviii Figures ...
Страница 452: ...434 Troubleshooting the Tape Library ...
Страница 456: ...438 Library Drawings Library Rear View Figure 32 ML6020 Rear View ...
Страница 463: ...PowerVault ML6000 Maintenance Guide 445 Figure 42 Model 1 Picker Assembly Figure 43 Model 2 Picker Assembly ...
Страница 466: ...448 Library Drawings Figure 46 Model 1 Parking Tab Parked Figure 47 Model 2 Parking Tab Parked ...
Страница 467: ...PowerVault ML6000 Maintenance Guide 449 Library Control Blade LCB Figure 48 Library Control Blade ...
Страница 468: ...450 Library Drawings Power Supplies Figure 49 Power Supplies ...
Страница 475: ...PowerVault ML6000 Maintenance Guide 457 Rack mounted Library Figure 56 Rack mounted Library Front ...
Страница 477: ...PowerVault ML6000 Maintenance Guide 459 Figure 58 Electrical System 5U Library Control Module ...
Страница 478: ...460 Library Drawings Figure 59 LCB Functions ...
Страница 479: ...PowerVault ML6000 Maintenance Guide 461 ...
Страница 480: ...462 Library Drawings Figure 60 Accessor Control Block Figure 61 Door and Import Export Board DIEB ...
Страница 481: ...PowerVault ML6000 Maintenance Guide 463 Figure 62 Door and Display Block Figure 63 Power System Block ...
Страница 482: ...464 Library Drawings Figure 64 Fan Control Board ...
Страница 483: ...PowerVault ML6000 Maintenance Guide 465 Figure 65 Library Cables ...
Страница 484: ...466 Library Drawings Figure 66 Library System Grounding ...
Страница 485: ...PowerVault ML6000 Maintenance Guide 467 Figure 67 Library Power System ...
Страница 486: ...468 Library Drawings ...
Страница 494: ...476 Glossary Y axis Y position The vertical position of the library s robotic arm ...