Engine System Centaur Service Manual
Ontario Drive & Gear Limited www.centaur8x8.ca
(519) 662-2840 FAX (519) 662-2421
EN-32
48. Remove the
lower
rad hose and extender tube that is connected to the outlet side of
the cooling system.
Photo EN-65
49. Remove the temperature gauge sensor located just below the thermostat.
Photo EN-66
47. Remove the
upper
rad hose and extension tube connected to the top of the thermo
-
stat.
Photo EN-64
Engine Sub-Assembly
1. Apply teflon pipe sealant to the threads
of the temperature gauge sensor and
install below the thermostat.
Photo EN-66
If the sensor is being installed into a new
engine, you must first remove the brass plug
below the thermostat.
2. Install the lower
rad hose and extender tube to the outlet side of the cooling system.
Photo EN-65
above.
Apply a little white grease to the inside diameter of both ends of the rad hose. This will
ease the assembly of the hose to the outlet side of the cooling system. It will also help when
assembling the extension tube to the other end.
EN-64
EN-65
EN-66
Содержание 2001 950
Страница 2: ......
Страница 4: ......
Страница 286: ...Centaur Service Manual Vehicle Bodies Ontario Drive Gear Limited www centaur8x8 ca 519 662 2840 FAX 519 662 2421 VB 5 ...
Страница 329: ...Wheels Axles Chains Centaur Service Manual Ontario Drive Gear ltd 519 662 2840 FAX 519 662 2421 ...
Страница 353: ......
Страница 413: ......
Страница 416: ...saue Axial Piston Pumps Motors and Transmissions Technical Information Series 70 15 Series ...
Страница 429: ...14 saue Axial Piston Pumps Motors and Transmissions Series 70 15 Series Notes ...
Страница 446: ...30 saue Axial Piston Pumps Motors and Transmissions Series 70 15 Series Dimensions 15 Series U Style Transmission ...
Страница 447: ...31 saue Axial Piston Pumps Motors and Transmissions Series 70 15 Series Notes ...
Страница 449: ......