8-4 Troubleshooting
POST Error Messages
When POST detects an error, it displays an error message on the display unit screen. The following table lists error messages
and actions to take.
IMPORTANT:
Take a note on the messages displayed before consulting with your service
representative. Alarm messages are useful information for maintenance.
Error
code Error message
Recommended Action
0200
Failure Fixed Disk.
Contact your service representative.
0210
Stuck Key.
Disconnect the keyboard and connect it again.
0211 Keyboard
error
Disconnect the keyboard and connect it again. If the error cannot be
corrected, contact your service representative.
0213
Keyboard locked - Unlock key switch.
Release the lock of the key switch. If the error cannot be corrected in
spite of the release of the lock, contact your service representative.
0220
Monitor type does not match CMOS - Run
SETUP.
Start the SETUP. If the error cannot be corrected in spite of the start of
SETUP, contact your service representative.
0230
System RAM Failed at offset.
0231
Shadow Ram Failed at offset.
0232
Extended RAM Failed at address line.
Contact your service representative.
0250
System battery is dead - Replace and run
SETUP.
Contact your service representative to replace the battery. (After
restarting the computer, start the SETUP to provide the setting again.)
0251
System CMOS checksum bad - Default
configuration used.
The default values have just been set. Start the SETUP to provide the
setting again. If the error cannot be corrected, contact your service
representative.
0252
Password checksum bad - Passwords
cleared.
The password has just been cleared. Start the SETUP to provide the
setting again.
0260
System timer error.
0270
Real time clock error.
0271
Check date and time setting.
Start the SETUP to set the date and time again. If the same error
occurs successively in spite of the resetting, contact your service
representative.
0280
Previous boot incomplete - Default
configuration used.
Start the SETUP to provide the setting again.
0281
Memory size found by POST differed from
EISA CMOS.
Initialize EISA CMOS.
02D0
System cache error - Cache disabled.
The cache cannot be used. Contact your service representative.
02D1
System Memory exceeds the CPU's caching
limit.
02F4
EISA CMOS not write able.
02F5 DMA
Test
Failed.
02F6
Software NMI Failed.
02F7
Fail-safe Timer NMI Failed.
Contact your service representative.
0B22
Processors are installed out of order.
Request the maintenance to replace the CPU.
0B28
Unsupported CPU detected on CPU socket
1.
0B29
Unsupported CPU detected on CPU socket
2.
Make sure that the server supports the CPU. If you are not sure,
contact your service representative to request the maintenance.
0B42 Resource
Conflict
0B43
Warning: IRQ not configured
0B45
System configuration Data Write Error
Contact your service representative.
0B60
CPU1_DIMM1 has been disabled
0B61
CPU1_DIMM2 has been disabled
0B62
CPU1_DIMM3 has been disabled
0B63
CPU1_DIMM4 has been disabled
0B64
CPU1_DIMM5 has been disabled
0B65
CPU1_DIMM6 has been disabled
0B66
CPU2_DIMM1 has been disabled
0B67
CPU2_DIMM2 has been disabled
0B68
CPU2_DIMM3 has been disabled
0B69
CPU2_DIMM4 has been disabled
Contact your service representative.
Содержание NovaScale R460 E2
Страница 1: ...NovaScale R460 E2 User s Guide NOVASCALE REFERENCE 86 A1 47FB 00...
Страница 2: ......
Страница 8: ......
Страница 21: ...Notes on Using Your Server 1 3 Internal View...
Страница 34: ...1 16 Notes on Using Your Server This page is intentionally left blank...
Страница 42: ...2 8 General Description Internal View The processor air duct is omitted for clarity 2 5 inch Disk Model...
Страница 115: ...Configuring Your Server 4 31 Physical View of WebBIOS Property of Physical Device of Universal RAID Utility...
Страница 146: ...4 62 Configuring Your Server 6 Click Home at the lower left of the screen to go back to WebBIOS Top Menu...
Страница 228: ...6 8 Installing and Using Utilities 4 Click Parameter File Creator Parameter File Creator will appear...
Страница 290: ...8 36 Troubleshooting When you use a local console When you use a remote console 6 Each tool is selected and it starts...
Страница 392: ...9 96 Upgrading Your Server This page is intentionally left blank...
Страница 402: ......
Страница 404: ...C 2 IRQ This page is intentionally left blank...
Страница 429: ...Installing Windows Server 2008 D 25 4 Activate Windows The Windows activation is complete...
Страница 456: ......
Страница 482: ...G 2 Using a Client Computer which has a CD Drive This page is intentionally left blank...
Страница 486: ...H 4 Product Configuration Record Table This page is intentionally left blank...
Страница 489: ......
Страница 490: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 46FB 00...