4-28 Configuring Your Server
Reconstruction
The reconstruction feature is used to change configuration and/or RAID level of existing virtual disk. The Reconstruction
contains the following three features, however, the Internal RAID Controller supports "Migration with addition" only.
IMPORTANT:
You can use WebBIOS for Reconstruction. Universal RAID Utility does not
support Reconstruction.
Removed physical drive
Unsupported.
Migration only
Unsupported.
Migration with addition
Use this feature to add HDDs to existing virtual disk. The execution patterns are as shown below (
α
: Number of HDDs to be
added).
Before execution
After execution
RAID
level
Number of
HDDs
RAID
level
Number of HDDs
Description
RAID0 x
RAID0 x+
α
Capacity increased: equivalent to
α
HDDs
RAID0
1
RAID1
2
Capacity remains unchanged.
RAID0 x
RAID5 x+
α
Capacity increased: equivalent to
α
-1 HDDs
RAID0 x
RAID6 x+
α
(
α
=2 or more)
Capacity increased: equivalent to
α
-2 HDDs
RAID1 2
RAID0 2+
α
Capacity increased: equivalent to
α
+1 HDDs
RAID1 2
RAID5 2+
α
Capacity increased: equivalent to
α
HDDs
RAID1 2
RAID6 2+
α
Capacity increased: equivalent to
α
-1 HDDs
RAID5 x
RAID0 x+
α
Capacity increased: equivalent to
α
+1 HDDs
RAID5 x
RAID5 x+
α
Capacity increased: equivalent to
α
HDDs
RAID5 x
RAID6 x+
α
Capacity increased: equivalent to
α
-1 HDDs
RAID6 x
RAID0 x+
α
Capacity increased: equivalent to
α
+2 HDDs
RAID6 x
RAID5 x+
α
Capacity increased: equivalent to
α
+1 HDDs
RAID6 x
RAID6 x+
α
Capacity increased: equivalent to
α
HDDs
IMPORTANT:
Note the following for the Reconstruction:
Be sure to make backup copy of data and perform Consistency Check before starting
Reconstruction.
The Reconstruction is disabled in the configuration where several virtual disks are defined in
one disk group
During Reconstruction, the processing rate is decreased due to much load.
The Reconstruction can be performed for the degraded or partially degraded virtual disk.
However, it is recommended to execute Rebuild to recover the virtual disk, then execute
Reconstruction.
During Reconstruction, do not shutdown or reboot the server. If the server is shutdown by an
unforeseen accident such as power interruption, turn on the power again as soon as possible.
The Reconstruction is automatically restarted.
In some configuration, Background Initialize may start automatically upon completion of
Reconstruction.
Содержание NovaScale R460 E2
Страница 1: ...NovaScale R460 E2 User s Guide NOVASCALE REFERENCE 86 A1 47FB 00...
Страница 2: ......
Страница 8: ......
Страница 21: ...Notes on Using Your Server 1 3 Internal View...
Страница 34: ...1 16 Notes on Using Your Server This page is intentionally left blank...
Страница 42: ...2 8 General Description Internal View The processor air duct is omitted for clarity 2 5 inch Disk Model...
Страница 115: ...Configuring Your Server 4 31 Physical View of WebBIOS Property of Physical Device of Universal RAID Utility...
Страница 146: ...4 62 Configuring Your Server 6 Click Home at the lower left of the screen to go back to WebBIOS Top Menu...
Страница 228: ...6 8 Installing and Using Utilities 4 Click Parameter File Creator Parameter File Creator will appear...
Страница 290: ...8 36 Troubleshooting When you use a local console When you use a remote console 6 Each tool is selected and it starts...
Страница 392: ...9 96 Upgrading Your Server This page is intentionally left blank...
Страница 402: ......
Страница 404: ...C 2 IRQ This page is intentionally left blank...
Страница 429: ...Installing Windows Server 2008 D 25 4 Activate Windows The Windows activation is complete...
Страница 456: ......
Страница 482: ...G 2 Using a Client Computer which has a CD Drive This page is intentionally left blank...
Страница 486: ...H 4 Product Configuration Record Table This page is intentionally left blank...
Страница 489: ......
Страница 490: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 46FB 00...