22.
Install the service access cover
1.
Place the service access cover
(A)
on the
top of the system, about 25 mm (1 in.)
from the front of the system.
2.
Hold the service access cover against the
system unit and slide it toward the front
of the system. The tabs of the service
access cover slide beneath the upper
chassis ledge.
3.
Align the two thumbscrews
(B)
located on
the back of the service access cover with
the two holes on the back of the system
chassis.
4.
Tighten the thumbscrews to secure the
service access cover.
23.
Place into operating position
1.
To unlock the rail safety latches
(B)
, slide
the latches towards the front of the
system.
2.
Push the system unit
(A)
back into the
rack until both system-unit release latches
have locked into position.
Note:
Ensure that the cables at the back of
the system do not catch or bind as you
push the system unit back into the rack.
Chapter 1. Removing and replacing FRUs
55
Содержание ESCALA PL860T/R
Страница 1: ...ESCALA ESCALA PL860T R Removal and Replacement Procedures REFERENCE 86 A1 88FA 01...
Страница 2: ......
Страница 6: ...iv Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 194: ...186 Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 217: ......
Страница 218: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 88FA 01...